Vibration arthrometry in the patients with failed total knee replacement.
MedLine Citation:
PMID:  10721629     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
This is a preliminary research on the vibration arthrometry of artificial knee joint in vivo. Analyzing the vibration signals measured from the accelerometer on patella, there are two speed protocols in knee kinematics: 1) 2 degrees/s, the signal is called "physiological patellofemoral crepitus (PPC)", and 2) 67 degrees/s, the signal is called "vibration signal in rapid knee motion". The study has collected 14 patients who had revision total knee arthroplasty due to prosthetic wear or malalignment represent the failed total knee replacement (FTKR), and 12 patients who had just undergone the primary total knee arthroplasty in the past two to six months and have currently no knee pain represent the normal total knee replacement (NTKR). FTKR is clinically divided into three categories: metal wear, polyethylene wear of the patellar component, and no wear but with prosthesis malalignment. In PPC, the value of root mean square (rms) is used as a parameter; in vibration signals in rapid knee motion, autoregressive modeling is used for adaptive segmentation and extracting the dominant pole of each signal segment to calculate the spectral power ratios in f < 100 Hz and f > 500 Hz. It was found that in the case of metal wear, the rms value of PPC signal is far greater than a knee joint with polyethylene wear and without wear, i.e., PPC signal appears only in metal wear. As for vibration signals in rapid knee motion, prominent time-domain vibration signals could be found in the FTKR patients with either polyethylene or metal wear of the patellar component. We also found that for normal knee joint, the spectral power ratio of dominant poles has nearly 80% distribution in f < 100 Hz, is between 50% and 70% for knee with polyethylene wear and below 30% for metal wear, whereas in f > 500 Hz, spectral power ratio of dominant poles has over 30% distribution in metal wear but only nonsignificant distribution in polyethylene wear, no wear, and normal knee. The results show that vibration signals in rapid knee motion can be used for effectively detecting polyethylene wear of the patellar component in the early stage, while PPC signals can only be used to detect prosthetic metal wear in the late stage.
Authors:
C C Jiang; J H Lee; T T Yuan
Related Documents :
2345439 - Effects of data smoothing on the reconstruction of helical axis parameters in human joi...
19849859 - Biomechanical analysis of the relation between movement time and joint moment developme...
19349049 - Efficacy and stability performance of traditional versus motion sensor-assisted strateg...
2026199 - Coupled and uncoupled limb oscillations during paw-shake response.
18486749 - Force-displacement relationship during anteroposterior mobilization of the ankle joint.
3400419 - Recording of chick embryo movements and their correlation with joint development.
20653449 - Melatonin-synthesizing enzymes in pineal, retina, liver, and gut of the goldfish (caras...
25154099 - Contrasting evolutionary demography induced by fishing: the role of adaptive phenotypic...
23722709 - Electroretinographic assessment of retinal function at high altitude.
Publication Detail:
Type:  Clinical Trial; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  IEEE transactions on bio-medical engineering     Volume:  47     ISSN:  0018-9294     ISO Abbreviation:  IEEE Trans Biomed Eng     Publication Date:  2000 Feb 
Date Detail:
Created Date:  2000-04-11     Completed Date:  2000-04-11     Revised Date:  2009-11-11    
Medline Journal Info:
Nlm Unique ID:  0012737     Medline TA:  IEEE Trans Biomed Eng     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  219-27     Citation Subset:  IM    
Affiliation:
Department of Orthopaedic Surgery, National Taiwan University Hospital, Taipei, Taiwan, R.O.C.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Biomechanics
Equipment Failure Analysis / methods*
Female
Humans
Knee Joint / physiopathology*
Knee Prosthesis*
Male
Materials Testing*
Range of Motion, Articular / physiology
Signal Processing, Computer-Assisted
Vibration*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Quality driven gold washing adaptive vector quantization and its application to ECG data compression...
Next Document:  Time-frequency analysis of myoelectric signals during dynamic contractions: a comparative study.