Variation of the sensitometric characteristics of seven mammographic films with processing conditions.
MedLine Citation:
PMID:  15326045     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The effect of different processing conditions on the sensitometric characteristics of mammographic films was investigated and the implications of this effect on clinical practice are discussed. Three Agfa (MR5-II, HDR and HT), two Kodak (MinR-M, MinR-2000), one Fuji (AD-M) and one Konica (CM-H) single emulsion mammographic films were used. For each film type a 21-step sensitometric strip was developed in seven different processing conditions involving the use of four processors, five developing times and four chemistries. The different processing conditions produced a variable effect on the sensitometric characteristics of the mammographic films. While some films seemed relatively insensitive, others were greatly affected. Furthermore, not all the sensitometric parameters of a film were affected in the same way. For example, a change of processing conditions in some cases increased speed and decreased contrast but in some other cases increased both speed and contrast. Different mammographic films present different sensitometric characteristics that can be altered by processing conditions. Thus, in a mammographic facility any change in film processor/processing cycle or chemistry should be carefully investigated before mammograms of patients are acquired. Furthermore, the results of film comparisons under certain processing conditions should not be generalized to other processing conditions.
Authors:
I A Tsalafoutas; A D Dimakopoulou; E D Koulentianos; A N Serefoglou; E N Yakoumakis
Related Documents :
16851835 - Nature and properties of ultrathin nanocrystalline gold films formed at the organic-aqu...
12707755 - Comparative investigations of structure and properties of bcn coatings deposited by the...
18040405 - Composite optical waveguide composed of a tapered film of bromothymol blue evaporated o...
19099365 - Noncovalent self-assembling nucleic acid-lipid based materials.
17025125 - Controllable synthesis of vertically aligned zno nanorod arrays in aqueous solution.
2600735 - Aztreonam for injection (lyophilized): development of an automated solution batching pr...
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  The British journal of radiology     Volume:  77     ISSN:  0007-1285     ISO Abbreviation:  Br J Radiol     Publication Date:  2004 Aug 
Date Detail:
Created Date:  2004-08-24     Completed Date:  2004-09-30     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0373125     Medline TA:  Br J Radiol     Country:  England    
Other Details:
Languages:  eng     Pagination:  666-71     Citation Subset:  AIM; IM    
Affiliation:
Medical Physics Unit and Radiology Department "Konstantopoulio - Agia Olga" Hospital, 3-5 Agias Olgas, Nea Ionia, 142 33, Athens, Greece.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Female
Humans
Mammography / instrumentation*,  standards
Reproducibility of Results
Technology, Radiologic
X-Ray Film / standards*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  16-detector multislice CT: dosimetry estimation by TLD measurement compared with Monte Carlo simulat...
Next Document:  Implementation of a spreadsheet program for calculation of equivalent square field size.