Variation in quantitative respirator fit factors due to fluctuations in leak size during fit testing.
MedLine Citation:
PMID:  8209835     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Variation in fit factors during quantitative respirator fit testing was studied for a high degree of fit (aerosol fit factors > 1000) and a low degree of fit (aerosol fit factors < 1000). In a controlled human study, fit factors were determined sequentially for three different exercises by (1) an aerosol fit test (using a portable condensation nuclei counter and room aerosol as the test agent) and (2) the newly developed dichotomous-flow fit test (Dichot). For the higher level of respirator fit, the aerosol fit factors were 30 to 60 times the corresponding flow fit factors, and for the lower level of respirator fit they were 2 to 4 times the flow fit factors. A coefficient of variation (CV) of 84% (GSD 1.6) for the higher respirator fit and 178% (GSD 2.2) for the lower respirator fit data was observed in the human study when aerosol fit factors for the three exercises were pooled. In a similar mannequin study, the center sampling probe gave aerosol fit factors with a CV of 5.4% (GSD 1.05). The flow fit factors for all three exercises pooled had a CV of 36% (GSD 1.3) for the higher respirator fit and 40% (GSD 1.5) for the lower respirator fit data, while the mannequin study gave flow fit factors with a CV of 2.2% (GSD 1.02). Thus, the variation in fit factors obtained in the human study was much higher than that obtained in a mannequin study. However, the variation in the aerosol method relative to the flow method, in the human study, os of the same order of magnitude as in the mannequin study.(ABSTRACT TRUNCATED AT 250 WORDS)
Authors:
U Krishnan; K Willeke; A Juozaitis; T Myojo; G Talaska; R Shukla
Related Documents :
21282635 - Signaling mechanisms in the restoration of impaired immune function due to diet-induced...
19927145 - The low-fitness phenotype as a risk factor: more than just being sedentary?
12395615 - Electromyographic validation of the trapezius and serratus anterior muscles in rowing e...
12395145 - The relationship between physical activity and self-image and problem behaviour among a...
19244585 - Prolonged exercise training induces long-term enhancement of hsp70 expression in rat pl...
3591685 - Predictive value of clinical and exercise variables for detection of coronary artery di...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't; Research Support, U.S. Gov't, P.H.S.    
Journal Detail:
Title:  American Industrial Hygiene Association journal     Volume:  55     ISSN:  0002-8894     ISO Abbreviation:  Am Ind Hyg Assoc J     Publication Date:  1994 Apr 
Date Detail:
Created Date:  1994-07-13     Completed Date:  1994-07-13     Revised Date:  2007-11-14    
Medline Journal Info:
Nlm Unique ID:  0371160     Medline TA:  Am Ind Hyg Assoc J     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  309-14     Citation Subset:  IM    
Affiliation:
Department of Environmental Health, University of Cincinnati, OH 45267-0056.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Air / analysis
Equipment Design
Humans
Pressure
Reproducibility of Results
Respiratory Protective Devices*
Grant Support
ID/Acronym/Agency:
R01-OH-01301/OH/NIOSH CDC HHS

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Pharmacists' use of safety caps on refilled prescriptions.
Next Document:  Visual field loss while wearing full-face respiratory protection.