Validity of identifying patient-prosthesis mismatch from the indexed effective orifice area.
MedLine Citation:
PMID:  18836879     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The main problem that arises from patient-prosthesis mismatch after aortic valve replacement is a residual high transvalvular pressure gradient, resulting in left ventricular overload. It was demonstrated by Pibarot and Dumesnil that the indexed effective orifice area should be larger than 0.85-0.90 cm2/m2 to prevent any significant transvalvular pressure gradient after operation. However, we have encountered a higher residual transvalvular pressure gradient than expected in some patients with an aortic stented bioprosthesis with an indexed effective orifice area greater than 0.85 cm2/m2. Based on our data, an indexed effective orifice area of less than 1.25 cm2/m2 might be considered the threshold for patient-prosthesis mismatch in patients with a stented bioprosthesis because this indexed effective orifice area is associated with a low mean transvalvular pressure gradient (less than 10 mmHg). The practical implications include the necessity to consider the hemodynamic performance of each prosthesis type when seeking to define patient-prosthesis mismatch and abnormally or significant high postoperative gradients that lead to an increased left ventricular workload, so as to avoid residual significant transvalvular pressure gradients and higher rates of morbidity and mortality.
Authors:
Yoshimasa Sakamoto; Kazuhiro Hashimoto; Hiroshi Okuyama; Shinichi Ishii; Noriyasu Kawada; Takahiro Inoue
Related Documents :
17252209 - Remotely adjustable check-valves with an electrochemical release mechanism for implanta...
7954499 - A nonlinear biomechanical model for evaluation of cerebrospinal fluid shunt systems.
4031289 - Continuous wave doppler determination of right ventricular pressure: a simultaneous dop...
8573909 - Ventricular pressure slope and bileaflet mechanical heart valve closure.
6711439 - In vitro verification of doppler prediction of transvalve pressure gradient and orifice...
2278709 - Relation between three-dimensional geometry of the inflow tract to the orifice and the ...
2830219 - Dimethylthiourea attenuates endotoxin-induced acute respiratory failure in pigs.
7201339 - Long-lasting cardiovascular depression induced by acupuncture-like stimulation of the s...
9447329 - Relationship between haemodynamics and morphology in pulmonary hypertension. a quantita...
Publication Detail:
Type:  Journal Article     Date:  2008-10-05
Journal Detail:
Title:  Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs     Volume:  11     ISSN:  1434-7229     ISO Abbreviation:  J Artif Organs     Publication Date:  2008  
Date Detail:
Created Date:  2008-10-06     Completed Date:  2009-01-27     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9815648     Medline TA:  J Artif Organs     Country:  Japan    
Other Details:
Languages:  eng     Pagination:  163-4     Citation Subset:  IM    
Affiliation:
Department of Cardiovascular Surgery, Jikei University School of Medicine, 3-25-8 Nishishinbashi, Minato-ku, Tokyo, 105-8461, Japan. ysakamoto@jikei.ac.jp
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Aortic Valve / anatomy & histology*,  surgery*
Bioprosthesis*
Heart Valve Prosthesis*
Humans
Prosthesis Fitting