Validity of an arterial pressure waveform analysis device: does the puncture site play a role in the agreement with intermittent pulmonary artery catheter thermodilution measurements?
MedLine Citation:
PMID:  19700347     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.
Authors:
Sebastian Schramm; Eric Albrecht; Philippe Frascarolo; Pierre-Guy Chassot; Donat R Spahn
Related Documents :
10376917 - The valve of vieussens: an important cause of difficulty in advancing catheters into th...
9807747 - A fast responding intra-arterial ph electrode for use in the peripheral artery of adult...
23518197 - Renovascular hypertension associated with pseudoaneurysm following blunt trauma.
22576397 - Paradoxical cerebral air embolism occurred with postural change during rehabilitation, ...
1252127 - Membrane filters. additional safety for intra-arterial infusions.
10201047 - Stenting therapy for stenosing airway disease.
Publication Detail:
Type:  Comparative Study; Journal Article; Research Support, Non-U.S. Gov't; Validation Studies     Date:  2009-08-22
Journal Detail:
Title:  Journal of cardiothoracic and vascular anesthesia     Volume:  24     ISSN:  1532-8422     ISO Abbreviation:  J. Cardiothorac. Vasc. Anesth.     Publication Date:  2010 Apr 
Date Detail:
Created Date:  2010-04-05     Completed Date:  2010-11-08     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9110208     Medline TA:  J Cardiothorac Vasc Anesth     Country:  United States    
Other Details:
Languages:  eng     Pagination:  250-6     Citation Subset:  IM    
Copyright Information:
Copyright (c) 2010 Elsevier Inc. All rights reserved.
Affiliation:
Department of Anesthesiology, University Hospital Lausanne, Lausanne, Switzerland. sebastian.schramm@chuv.ch
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Blood Flow Velocity / physiology
Catheterization, Peripheral / instrumentation,  methods*,  standards*
Female
Humans
Male
Middle Aged
Monitoring, Intraoperative / instrumentation,  methods*,  standards*
Prospective Studies
Pulmonary Artery / physiology*
Punctures*
Thermodilution / instrumentation,  methods

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Left Ventricular Longitudinal Strain for Perioperative Cardiac Monitoring in Aortic Aneurysm Surgery...
Next Document:  Uncalibrated Radial and Femoral Arterial Pressure Waveform Analysis for Continuous Cardiac Output Me...