Validation of volume and mass assessments for human fetal heart imaging by 4-dimensional spatiotemporal image correlation echocardiography: in vitro balloon model experiments.
MedLine Citation:
PMID:  15328429     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: This study was designed to validate a slow-sweep real-time 4-dimensional (4D) spatiotemporal image correlation method for producing quantitatively accurate dynamic fetal heart images using an in vitro pulsatile balloon model and apparatus. METHODS: To model fetal heart chambers, asymmetric double-walled finger stalls (tips of surgical latex gloves) were used and attached to a laboratory-designed circuit that allowed calibrated changes in the inner balloon volume as well as an intermediate gel mass interposed between the 2 layers. The water-submerged model was attached to a small-volume pulsatile pump to produce phasic changes in volume within the inner balloon at a fixed rate. A sonography system with 4D spatiotemporal image correlation (STIC) capabilities was used for 3-dimensional (3D) and 4D data acquisition. Volume data were analyzed by customized radial summation techniques with 4D data analysis software and compared with known volumes and masses. RESULTS: Fifty-six individual volumes ranging from 2.5 to 10 mL were analyzed. Volume and mass measurements with 4D STIC were highly correlated (R2 > 0.90). The mean percentage error was better (<6%) for volumes exceeding 4 mL and was as low as 0.3% for 6-mL estimations. Measurements in the diastolic phase were the most accurate, followed by mass estimations equivalent to chamber walls. There was a wider range of percentage error in the lowest volumes tested (2.5 mL), which might have arisen from difficulties in spatial resolution or distortions from within the model apparatus itself. Resolution limitations of 4D technology in combination with extremely small volume targets may explain higher error rates at these small volumes. CONCLUSIONS: Four-dimensional STIC is an acceptably accurate method for volume and mass estimations in the ranges comparable with mid- and late-gestation fetal hearts. It is particularly accurate for diastolic estimations, for chamber wall mass measurements, and at volumes of greater than 2.5 mL. This study validates use of 4D STIC technology to overcome the limitations of nongated 3D technology for phasic and quantitative assessments in fetal echocardiography.
Authors:
Aarti Hejmadi Bhat; Virginia N Corbett; Ruolan Liu; Nathan D Carpenter; Nick W Liu; Anna M Wu; Graham D Hopkins; Xiaokui Li; David J Sahn
Related Documents :
11975649 - Replication of human tracheobronchial hollow airway models using a selective laser sint...
10719999 - A simple method to check the dynamic performance of electrical impedance tomography sys...
6592979 - A quantitative technique for assessing nasal airway impairment.
8624909 - Scaling of organ subunits in adult mammals and birds: a model.
10757619 - Validation of bio-impedance spectroscopy: effects of degree of obesity and ways of calc...
9674159 - Surface-weighted star volume: concept and estimation.
19508089 - Heterogeneous nucleation on convex spherical substrate surfaces: a rigorous thermodynam...
11707079 - On the marriage of cognition and neuroscience.
10486949 - Graphical tools for rflp measurement quality assurance: laboratory performance charts.
Publication Detail:
Type:  In Vitro; Journal Article; Validation Studies    
Journal Detail:
Title:  Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine     Volume:  23     ISSN:  0278-4297     ISO Abbreviation:  J Ultrasound Med     Publication Date:  2004 Sep 
Date Detail:
Created Date:  2004-08-25     Completed Date:  2004-12-21     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  8211547     Medline TA:  J Ultrasound Med     Country:  United States    
Other Details:
Languages:  eng     Pagination:  1151-9     Citation Subset:  IM    
Affiliation:
Oregon Health and Science University, Portland 97239-3098, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Echocardiography, Four-Dimensional*
Fetal Heart / ultrasonography*
Humans
Image Processing, Computer-Assisted
Models, Cardiovascular*
Stroke Volume
Ultrasonography, Prenatal*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Endoscopic sonographically guided fine-needle aspiration yield in submucosal tumors of the gastroint...
Next Document:  Serum cholesterols have a more important role than triglycerides in determining intima-media thickne...