Abstract/OtherAbstract:
The validation of a blood flow meter is presented. This flow meter is based on the transit time method that uses two ultrasound transducers and a reflector. The measuring is based on the time difference of the upstream and the downstream ultrasound transit time. The validation was based on the norm ANSI Std. N42.17A-2003 of blood flow protocol. We used a flow simulator system with 3 mm pipe, bi-distilled and desgasificated water as fluid. Flow simulator system uses a constant flow pump, regulated by a valve, and a peristaltic flow pump, regulated by a variable voltage source, like flow source through the pipe.
Authors:
R Ortega-Palacios; E Moreno; L Leija; A Vera
Related Documents :
16112936 - The smartcanula: a new tool for remote access perfusion in limited access cardiac surgery.
8601046 - The blood saving potential of vortex versus roller pump with and without aprotinin.
16625656 - Effect of design on the performance of a dry powder inhaler using computational fluid d...
11799696 - Effect of diet viscosity on the operation of the pharyngeal pump in the blood-feeding b...
2627016 - Determination of glycohaemoglobin levels in ketonuric and non-ketonuric cows.
15885236 - Effects of some hematological parameters on whole blood tacrolimus concentration measur...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference     Volume:  1     ISSN:  1557-170X     ISO Abbreviation:  Conf Proc IEEE Eng Med Biol Soc     Publication Date:  2010  
Date Detail:
Created Date:  2010-11-24     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101243413     Medline TA:  Conf Proc IEEE Eng Med Biol Soc     Country:  United States    
Other Details:
Languages:  eng     Pagination:  178-81     Citation Subset:  IM    
Affiliation:
Electrical Engineering Department, CINVESTAV-IPN, C.P. 0736, Mexico D.F., Mexico.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Signal quality classification for an ambulatory monitoring system.
Next Document:  Use of a gelatin cryogel as biomaterial scaffold in the differentiation process of human bone marrow...