Validation of three professional devices measuring office blood pressure according to three different methods: the Omron BP10, the Omron HBP T105 and the Pic Indolor Professional.
MedLine Citation:
PMID:  20087217     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: Three professional devices for office blood pressure (BP) measurement, using three different algorithms to determine BP, were evaluated according to the International Protocol of the European Society of Hypertension. The Omron BP10 uses the oscillometric method, the Omron HBP T105 (module HBP-M3600) uses the smart inflation mode and high-speed measurement and the Pic Indolor Professional check is a hybrid sphygmomanometer. METHODS: The International Protocol of the European Society of Hypertension is divided into two phases and includes a total number of 33 participants on whom the validation is performed. In each study and for each participant, four BP measurements were performed simultaneously by two observers using mercury sphygmomanometers alternately with three measurements by the tested device. The difference between the observers and the device BP values was calculated for each measure. The 99 pairs BP differences were classified into three categories (<or=5, <or=10 and <or=15 mmHg). RESULTS: All three tested devices passed the first and the second phase of the validation process. The mean differences between the device and mercury readings were -0.02 +/- 3.7 and -2.2 +/- 3.9 mmHg for SBP and DBP, respectively, for the Omron BP10 device; 1.5 +/- 5.7 and -0.6 +/- 3.8 mmHg for the Omron HBP T105 device; and -0.6 +/- 1.7 and -0.4 +/- 1.5 mmHg for the Pic Indolor Professional device. CONCLUSION: Readings of the Omron BP10, the Omron HBP T105 and the Pic Professional check, fulfill the criteria of the International Protocol of the European Society of Hypertension. Therefore, these devices can be used in the clinic.
Authors:
Roland Asmar; Jos? Khabouth; Jimmy Mattar; Valerio Pecchioli; Giuseppe Germano
Related Documents :
19398107 - Lattice boltzmann simulations of droplet formation during microchannel emulsification.
7428397 - Measuring systolic arterial blood pressure. possible errors from extension tubes or dis...
8081537 - The flutter vrp1: a new personal pocket therapeutic device used as an adjunct to drug t...
10212377 - Evaluation of the profilomat ii ambulatory blood pressure system according to the proto...
8830347 - Neurochemical modulation of cardiovascular control in the nucleus tractus solitarius.
23269127 - Methods of blood pressure measurement in the icu.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't; Validation Studies    
Journal Detail:
Title:  Journal of hypertension     Volume:  28     ISSN:  1473-5598     ISO Abbreviation:  J. Hypertens.     Publication Date:  2010 Mar 
Date Detail:
Created Date:  2010-02-17     Completed Date:  2010-06-01     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8306882     Medline TA:  J Hypertens     Country:  England    
Other Details:
Languages:  eng     Pagination:  452-8     Citation Subset:  IM    
Affiliation:
Centre de M?decine Cardiovasculaire, Paris, France. ra@cmcv.org
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Blood Pressure*
Blood Pressure Monitors*
Female
Humans
Male
Middle Aged

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Association of angiotensinogen gene M235T and angiotensin-converting enzyme gene I/D polymorphisms w...
Next Document:  Arthroscopic mobilization of the hip joint in children with aseptic necrosis of the femur head.