BACKGROUND: A simple, rapid, inexpensive method for measuring the flow in a patient's vascular access would permit routine monitoring during haemodialysis, and hence provide information of access graft deterioration sufficiently early to increase the success of minimally invasive remedial procedures. This paper reports the validation of such a method in animals. METHODS: A PTFE graft was implanted in sheep between the carotid artery and the jugular vein. While the sheep was under general anaesthesia and on an haemodialysis circuit, ultrasound velocity in its blood was perturbed by the injection of a 5-10 ml bolus of isotonic NaCl. The pump tubing flow was measured by a transit-time blood flow meter. This flow was combined with the areas of perturbation generated by the injection before and after mixing in the access flow to estimate graft flow. The calculated graft flow was compared to flow measured directly by a transit-time probe on the same carotid artery. RESULTS: Over a 10-fold range, 120-1260 ml/min, graft flow measured by ultrasound velocity dilution agreed well with graft flow measured directly with a scatter of 76 ml/min about the regression line. CONCLUSION: Ultrasound velocity dilution provides a method for measuring flow in the graft accurate enough for clinical evaluation of patients on dialysis.
Authors:
R D Gleed; H J Harvey; A Dobson
Related Documents :
16935097 - Predictive value of intraoperative transit-time flow measurement for short-term graft p...
1346657 - Transcutaneous ultrasound measurement of blood-flow in internal mammary artery to coron...
7459527 - The value of the patency test in microvascular anastomosis: correlation between observe...
19379367 - Epidemiology and blood flow surveillance of the native arteriovenous fistula: a review ...
3456997 - Prostaglandins in diagnostic and therapeutic superior mesenteric artery pharmacoangiogr...
18815377 - Experimental characterization of shear transformation zones for plastic flow of bulk me...
Publication Detail:
Type:  Journal Article; Research Support, U.S. Gov't, P.H.S.    
Journal Detail:
Title:  Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association     Volume:  12     ISSN:  0931-0509     ISO Abbreviation:  Nephrol. Dial. Transplant.     Publication Date:  1997 Jul 
Date Detail:
Created Date:  1997-09-11     Completed Date:  1997-09-11     Revised Date:  2007-11-14    
Medline Journal Info:
Nlm Unique ID:  8706402     Medline TA:  Nephrol Dial Transplant     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  1464-7     Citation Subset:  IM    
Affiliation:
College of Veterinary Medicine, Cornell University, Ithaca, NY 14853, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Animals
Regional Blood Flow
Regression Analysis
Renal Dialysis*
Sheep
Ultrasonics
Grant Support
ID/Acronym/Agency:
1-R-43 DK50499-01/DK/NIDDK NIH HHS

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Ethylene oxide allergy in dialysis patients.
Next Document:  Errors in cervical smears: minimizing the risk of medicolegal consequences.