Document Detail


Validation and feasibility of intraoperative three-dimensional transesophageal echocardiographic cardiac output.
MedLine Citation:
PMID:  17959944     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: In this pilot study, we attempted to validate three-dimensional transesophageal echocardiography (3DTEE) cardiac output and assess its feasibility intraoperatively. METHODS: Twenty patients undergoing cardiac surgery underwent simultaneous cardiac output determinations during the clinically stable prebypass period by 3DTEE and thermodilution. RESULTS: The correlation coefficient between cardiac output measured by the two methods was 0.86. The 3DTEE mean bias was 0.27 L/min, limits of agreement -1.64 to 2.17 L/min (approximately +/-35%). Three-dimensional data acquisition averaged 43 s; postprocessing took 7 min. CONCLUSIONS: Three-dimensional TEE can measure cardiac output and is feasible perioperatively. Measurements have good correlation with thermodilution, though with a significant bias and wide limits of agreement.
Authors:
William C Culp; Timothy R Ball; Christopher J Burnett
Related Documents :
17975484 - Hemodynamic evaluation before liver transplantation: insights into the portal hypertens...
24504544 - Novel control system to prevent right ventricular failure induced by rotary blood pump.
17543244 - Impedance cardiography: more questions than answers.
3136684 - The non-invasive determination of cardiac output in children: a three-breath technique.
24220514 - Mobilization patterns of patients after an acute myocardial infarction: a pilot study.
8902584 - Effects of long-term oral administration of amiodarone on the ventricular repolarizatio...
Publication Detail:
Type:  Comparative Study; Journal Article; Validation Studies    
Journal Detail:
Title:  Anesthesia and analgesia     Volume:  105     ISSN:  1526-7598     ISO Abbreviation:  Anesth. Analg.     Publication Date:  2007 Nov 
Date Detail:
Created Date:  2007-10-25     Completed Date:  2007-12-03     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  1310650     Medline TA:  Anesth Analg     Country:  United States    
Other Details:
Languages:  eng     Pagination:  1219-23, table of contents     Citation Subset:  AIM; IM    
Affiliation:
Division of Cardiothoracic Anesthesiology, Department of Anesthesiology, Scott & White Hospital, The Texas A&M University System Health Science Center College of Medicine, Temple, TX 76508, USA. wculp@swmail.sw.org
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Aged, 80 and over
Cardiac Output / physiology*
Echocardiography, Three-Dimensional / methods,  standards*
Echocardiography, Transesophageal / methods,  standards
Feasibility Studies
Female
Humans
Male
Middle Aged
Monitoring, Intraoperative / methods,  standards*
Pilot Projects
Prospective Studies

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine