BACKGROUND AND PURPOSE:DTI is increasingly being used as a measure to study tissue damage in several neurologic diseases. Our aim was to investigate the comparability of DTI measures between different MR imaging magnets and platforms.MATERIALS AND METHODS:Two healthy volunteers underwent DTI on five 3T MR imaging scanners (3 Trios and 2 Signas) by using a matched 33 noncollinear diffusion-direction pulse sequence. Within each subject, a total of 16 white matter (corpus callosum, periventricular, and deep white matter) and gray matter (cortical and deep gray) ROIs were drawn on a single image set and then were coregistered to the other images. Mean FA, ADC, and longitudinal and transverse diffusivities were calculated within each ROI. Concordance correlations were derived by comparing ROI DTI values among each of the 5 magnets.RESULTS:Mean concordance for FA was 0.96; for both longitudinal and transverse diffusivities, it was 0.93; and for ADC, it was 0.88. Mean scan-rescan concordance was 0.96-0.97 for all DTI measures. Concordance correlations within platforms were, in general, better than those between platforms for all DTI measures (mean concordance of 0.96).CONCLUSIONS:We found that a 3T magnet and high-angular-resolution pulse sequence yielded comparable DTI measurements across different MR imaging magnets and platforms. Our results indicate that FA is the most comparable measure across magnets, followed by individual diffusivities. The comparability of DTI measures between different magnets supports the feasibility of multicentered clinical trials by using DTI as an outcome measure.
Authors:
R J Fox; K Sakaie; J-C Lee; J P Debbins; Y Liu; D L Arnold; E R Melhem; C H Smith; M D Philips; M Lowe; E Fisher
Related Documents :
7770108 - Resection of deep-seated gliomas using neuroimaging for stereotactic placement of guida...
7673038 - A system for stereotactic irradiation and magnetic resonance evaluations in the rat brain.
14606678 - Design and evaluation of an automatic procedure for detection of large misregistration ...
21844848 - Dosimetric impact of density variations in solid water 457 water-equivalent slabs.
9676768 - Retrocalcaneal bursitis in spondyloarthropathy: assessment by ultrasonography and magne...
18591598 - The detection of full thickness rotator cuff tears using ultrasound.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-12-15
Journal Detail:
Title:  AJNR. American journal of neuroradiology     Volume:  -     ISSN:  1936-959X     ISO Abbreviation:  -     Publication Date:  2011 Dec 
Date Detail:
Created Date:  2011-12-16     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8003708     Medline TA:  AJNR Am J Neuroradiol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Mellen Center for Multiple Sclerosis, Diagnostic Radiology, Quantitative Health Sciences, and Department of Biomedical Engineering, Cleveland Clinic, Cleveland, Ohio; Barrow Neurological Institute, Phoenix, Arizona; St. Luke's Medical Center, Milwaukee, Wisconsin; Montreal Neurological Institute, McGill University, Montreal, Quebec, Canada; and Genentech Inc., Seattle, Washington.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Spontaneous Normalization of Anti-Tissue Transglutaminase Antibody Levels Is Common in Children with...
Next Document:  Functional and Structural MR Imaging in Neuropsychiatric Disorders, Part 2: Application in Schizophr...