Validation of the Omron 705 IT oscillometric device for home blood pressure measurement in children and adolescents: the Arsakion School Study.
MedLine Citation:
PMID:  16810034     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: Limited evidence exists on the accuracy of oscillometric devices for blood pressure measurement in children. This study validated the Omron 705 IT monitor (Omron Healthcare Europe BV, Hoofddorp, The Netherlands) in normotensive children and adolescents. METHODS: Simultaneous blood pressure measurements were taken by two observers (connected mercury sphygmomanometers) four times, sequentially with three measurements by using the tested device. Absolute device-observer blood pressure differences were classified into three zones (within 5, 10 and 15 mmHg) and assessed using the European Society of Hypertension International Protocol criteria. The number of readings with a difference within 5 mmHg was calculated for each individual. The American Association for the Advancement of Medical Instrumentation criterion (mean difference+ or -SD <5+ or -8 mmHg) was also applied. RESULTS: A total of 197 study participants (591 readings) were included (99 boys, mean age+ or -SD 10.6+ or -2.4 years (range 6-16 years). The device produced 378 (64%), 532 (90%) and 579 (98%) measurements within 5, 10 and 15 mmHg, respectively, for systolic blood pressure, and 415 (70%), 525 (89%) and 577 (98%) measurements, respectively, for diastolic blood pressure. In all, 136 study participants (69%) had at least two systolic blood pressure differences within 5 mmHg and 16 (8%) had no differences within 5 mmHg (for diastolic blood pressure 147 (75%) and nine (5%) participants, respectively). Mean systolic blood pressure difference was 4.0+ or -4.8 mmHg and diastolic blood pressure -2.1+ or -5.9 mmHg and was <5+ or -8 mmHg in quartiles of participants divided by age, height, body mass index, arm circumference, blood pressure or pulse rate. CONCLUSIONS: The Omron 705 IT appears to be an accurate device for blood pressure measurement in normotensive children and adolescents.
Authors:
George S Stergiou; Nikolaos G Yiannes; Vayia C Rarra
Related Documents :
20575694 - Intrarenal pressures generated during deployment of various antiretropulsion devices in...
8558654 - Vacuum erection associated impotence and peyronie's disease.
19339994 - Calibration accuracy of hospital-based non-invasive blood pressure measuring devices.
6209664 - Techniques for improving cardiac performance with implantable devices.
9237134 - Anomalous intraocular pressure changes in chagas' disease elicited by postural test.
21090934 - Current status of blood pressure management after stroke.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't; Validation Studies    
Journal Detail:
Title:  Blood pressure monitoring     Volume:  11     ISSN:  1359-5237     ISO Abbreviation:  Blood Press Monit     Publication Date:  2006 Aug 
Date Detail:
Created Date:  2006-06-30     Completed Date:  2006-09-15     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  9606438     Medline TA:  Blood Press Monit     Country:  England    
Other Details:
Languages:  eng     Pagination:  229-34     Citation Subset:  IM    
Affiliation:
Hypertension Center, Third University Department of Medicine, Sotiria Hospital, Athens, Greece. gstergi@med.uoa.gr
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adolescent
Blood Pressure Monitoring, Ambulatory / instrumentation,  standards*
Child
Female
Humans
Hypertension / diagnosis*
Male
Oscillometry / instrumentation

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Validation of the A&D UA-705 device for self-measurement of blood pressure according to the British ...
Next Document:  Management of perioperative nutrition support.