Validation of the Microlife BPA100 Plus device for self-home blood pressure measurement according to the International Protocol.
MedLine Citation:
PMID:  16702824     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: Current guidelines recommend that only validated devices for blood pressure measurement should be used. This study presents the validation results of the Microlife BPA100 Plus monitor for self-home blood pressure measurement, according to the European Society of Hypertension International Protocol. METHODS: Fifteen study participants were included in phase 1 and an additional 18 in phase 2 (total 33). Simultaneous blood pressure measurements were taken by two trained observers (Y tube connected mercury sphygmomanometers) four times, sequentially with three measurements taken using the tested device. Absolute differences between observer and device blood pressure were classified into three zones (within 5, 10 and 15 mmHg). The number of readings with a difference within 5 mmHg was calculated for each individual. RESULTS: In phase 1, the device produced 32, 42 and 43 measurements within 5, 10 and 15 mmHg, respectively, for systolic blood pressure and 31, 45 and 45 for diastolic blood pressure. In phase 2.1, the device produced 71, 87 and 96 measurements within 5, 10 and 15 mmHg, respectively, for systolic blood pressure, and 71, 98 and 99 measurements for diastolic blood pressure. In phase 2.2, 26 participants had at least two of their differences within 5 mmHg and three participants had no differences within 5 mmHg for systolic blood pressure, whereas for diastolic blood pressure 24 and three participants, respectively. Mean systolic blood pressure differences were -2.0+/-6.0 mmHg and diastolic blood pressure differences were -3.1+/-4.1 mmHg. CONCLUSIONS: The Microlife BPA100 Plus device for self-home blood pressure measurement comfortably passes the validation requirements of the International Protocol and therefore can be recommended for clinical use in the adult population.
Authors:
George S Stergiou; Periklis P Giovas; Michalis S Neofytou; Dionysios N Adamopoulos
Related Documents :
2627764 - Measurement of the frequency response and common-mode gain of neonatal respiratory pres...
468704 - A technique for measuring frequency response of pressure, volume, and flow transducers.
6400644 - George w. crile: the pneumatic rubber suit.
12131074 - Terminal digit preference and single-number preference in the syst-eur trial: influence...
3194434 - Direct correlation between calcium content and blood pressure: a study of aortic coarct...
2923764 - Effects of general anaesthesia with halothane on antroduodenal motility, ph and gastric...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't; Validation Studies    
Journal Detail:
Title:  Blood pressure monitoring     Volume:  11     ISSN:  1359-5237     ISO Abbreviation:  Blood Press Monit     Publication Date:  2006 Jun 
Date Detail:
Created Date:  2006-05-16     Completed Date:  2006-08-03     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  9606438     Medline TA:  Blood Press Monit     Country:  England    
Other Details:
Languages:  eng     Pagination:  157-60     Citation Subset:  IM    
Affiliation:
Hypertension Center, Third University Department of Medicine, Sotiria Hospital, Athens, Greece. gstergi@med.uoa.gr
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Blood Pressure Determination / instrumentation*
Female
Home Nursing / methods
Humans
Hypertension / diagnosis
Male
Middle Aged
Self Care / instrumentation

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The population RDH index: a novel vector index and graphical method for statistical assessment of an...
Next Document:  Validation of a non-mercury digital auscultatory device with manual pressure registration (PMS Manda...