Validation of the Kingyield BP210 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension-International Protocol.
MedLine Citation:
PMID:  22185959     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
OBJECTIVE: The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor BP210 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension. METHODS: Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese participants (21 women, 51 years of mean age) using a mercury sphygmomanometer (two observers) and the BP210 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Data analysis was conducted using the ESHIP analyzer. RESULTS: The BP210 device successfully passed phase 1 of the validation study with a number of absolute differences between device and observers within 5, 10, and 15 mmHg for at least 33/45, 44/45, and 44/45 measurements, respectively. The device also achieved the targets for phase 2.1, with 77/99, 95/99, and 97/99 differences within 5, 10, and 15 mmHg, respectively for systolic blood pressure, and with 78/99, 97/99, and 99/99 within 5, 10, and 15 mmHg, respectively for diastolic blood pressure. In phase 2.2, 29 and 25 participants had at least two of the three device-observers differences within 5 mmHg (required≥22) for systolic blood pressure and diastolic blood pressure, respectively. CONCLUSION: The Kingyield wrist blood pressure monitor BP210 has passed the International Protocol requirements, and hence can be recommended for home use in adults.
Authors:
Wei-Fang Zeng; Qi-Fang Huang; Chang-Sheng Sheng; Yan Li; Ji-Guang Wang
Related Documents :
3359579 - Protective effects of long-term bradycardial pacing against catecholamine-induced myoca...
2596679 - Studies on australian snake venoms. part 1: the haemodynamic effects of brown snake (ps...
3407599 - Hemodynamic effects of dopexamine hydrochloride infusions of 48 to 72 hours' duration f...
7113899 - Beneficial hemodynamic effects of intravenous diazoxide in refractory congestive heart ...
15745129 - Validation of mean arterial pressure as an indicator of acute changes in cardiac output.
1239719 - Circulatory and respiratory adaptation in man to acute withdrawal and reinfusion of blood.
6524399 - The effect of pressor doses of angiotensin ii on autoregulation and intrarenal distribu...
7988129 - Influence of pressure- and flow-triggered synchronous intermittent mandatory ventilatio...
9352769 - Tension pneumopericardium following tracheoplasty for congenital tracheal stenosis.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-12-17
Journal Detail:
Title:  Blood pressure monitoring     Volume:  -     ISSN:  1473-5725     ISO Abbreviation:  -     Publication Date:  2011 Dec 
Date Detail:
Created Date:  2011-12-21     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9606438     Medline TA:  Blood Press Monit     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Centre for Epidemiological Studies and Clinical Trials, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Increased plasma thyroid hormone concentrations in LDL receptor deficient mice may be explained by i...
Next Document:  Elastic and anelastic relaxations in the relaxor ferroelectric Pb(Mg(1/3)Nb(2/3))O(3): I. Strain ana...