Validation of the DINAMAP ProCare blood pressure device according to the international protocol in an adult population.
MedLine Citation:
PMID:  16932038     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: Inaccurate blood pressure measurement has serious implications for both the patient and the health service. It results in inappropriate treatment and underestimation of clinical risk. Few automated devices have been shown to be accurate when compared with mercury sphygmomanometery. The DINAMAP ProCare has been developed to be accurate compared with an auscultatory standard. We used the International Protocol of the European Society of Hypertension to assess the accuracy of this device in an adult population. METHODS: Thirty-eight participants were recruited from outpatient clinics and staff at Groote Schuur Hospital, Cape Town, RSA. Of these, 33 participants who fulfilled the requirements of the International Protocol were selected for final analysis. Demographic data were obtained from each participant, followed by nine sequential same-arm measurements, alternating between two trained observers and the device. The last seven readings were analysed according to the guidelines of the International Protocol. RESULTS: The ProCare Monitor achieved all the required criteria of the International Protocol by successfully passing phase 1, phase 2.1 and phase 2.2 of the study protocol. The mean difference (standard deviation) for systolic and diastolic pressures, respectively, were -2.5 (5.4) and 0.5 (4.5) mmHg, which also falls within the passing criteria for the Association for the Advancement of Medical Instrumentation Standard (ANSI/AAMI SP-10). CONCLUSION: The DINAMAP ProCare Monitor can be recommended for clinical use in an adult population.
Authors:
Annemarie Reinders; Fayrouge Reggiori; Andrew H Shennan
Related Documents :
18496298 - A self-measurement device suitable for hospital use: validation of the spengler pro m a...
15915608 - Oscillometric blood pressure measurement: the methodology, some observations, and sugge...
17969368 - Validation of four automatic devices for self-measurement of blood pressure according t...
7422238 - A corneal transfixing irrigation/perfusion device: a new method for evacuation of hyphema.
9039088 - Pressor effects of endogenous opioid system during acute episodes of blood pressure inc...
1446958 - Clinical effect of indolidan in congestive heart failure.
Publication Detail:
Type:  Clinical Trial; Comparative Study; Journal Article; Research Support, Non-U.S. Gov't; Validation Studies    
Journal Detail:
Title:  Blood pressure monitoring     Volume:  11     ISSN:  1359-5237     ISO Abbreviation:  Blood Press Monit     Publication Date:  2006 Oct 
Date Detail:
Created Date:  2006-08-25     Completed Date:  2006-11-14     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  9606438     Medline TA:  Blood Press Monit     Country:  England    
Other Details:
Languages:  eng     Pagination:  293-6     Citation Subset:  IM    
Affiliation:
Department of Obstetrics & Gynaecology, Groote Schuur Hospital, Observatory, South Africa, and Maternal and Fetal Research Unit, King's College London School of Medicine, UK.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Blood Pressure Determination / instrumentation*,  standards*
Female
Humans
International Cooperation
Male
Mercury
Middle Aged
Reproducibility of Results
Sphygmomanometers / standards*
Chemical
Reg. No./Substance:
7439-97-6/Mercury

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Validation of three oscillometric blood pressure devices against auscultatory mercury sphygmomanomet...
Next Document:  Pubertal development in girls: secular trends.