Validation of the Braun BP 3550 wrist blood pressure measuring device with a position sensor and an EasyClick cuff according to the International Protocol in adults.
MedLine Citation:
PMID:  17303987     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: Among the electronic blood pressure measuring devices used for self-measurement of blood pressure by patients, models that measure at the wrist are becoming increasingly popular. Validation studies done with these equipments, however, are quite few. The objective of this study was to evaluate the accuracy of the Braun BP 3550 wrist blood pressure device against the mercury sphygmomanometer in adults according to the International Protocol criteria. METHODS: Fifty-four patients over 30 years of age were studied and classified on the basis of the range of the International Protocol. Blood pressure measurements at the wrist with the Braun BP 3550 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential blood pressure measurements were taken. A total of 33 individuals with randomly distributed arm circumferences were selected for the validation study. During the validation study, 99 measurements were obtained for comparison from 33 individuals. The first phase was performed on 15 individuals and if the device passed this phase, 18 more individuals were selected. RESULTS: Mean discrepancies and standard deviations of the device sphygmomanometer were 0.4+/-8.1 mmHg for systolic blood pressure and 2.1+/-5.8 mmHg for diastolic blood pressure in the study group. The device passed phase 1 in 15 individuals. In phase 2.1, from the total 99 comparisons, 65, 84 and 91 for systolic blood pressure and 62, 91 and 98 for diastolic blood pressure were <5, <10 and <15 mmHg, respectively. In phase 2.2, 23 individuals had at least two of the differences within 5 mmHg, and two had no differences within 5 mmHg for systolic blood pressure. In terms of diastolic blood pressure, 23 individuals had at least two of the differences within 5 mmHg and three had no differences within 5 mmHg. Braun BP 3550 passed phases 2.1 and 2.2 in the adult participants. CONCLUSION: The Braun BP 3550 wrist blood pressure device passed according to the International Protocol criteria and can be recommended for use in adults. Deviation from the average value, however, was greater in patients with high systolic blood pressure as compared with those with lower blood pressure.
Authors:
Nevzat Ilman; Sekip Altunkan; Nur Kayatürk; Erkan Altunkan
Related Documents :
22906957 - Hypertension and chronic kidney disease progression: why the suboptimal outcomes?
6723337 - Air entrapment in pressure monitoring lines.
2002667 - Clinical trials of a dual-sensor diagnostic pacemaker.
19021367 - Miniature fiber optic pressure sensor with composite polymer-metal diaphragm for intrad...
3214797 - Systolic pressure gradients between the wall of the left ventricle, the left ventricula...
2532997 - Regional distribution of the cardiac output and renal responses to atrial natriuretic p...
Publication Detail:
Type:  Journal Article; Validation Studies    
Journal Detail:
Title:  Blood pressure monitoring     Volume:  12     ISSN:  1359-5237     ISO Abbreviation:  Blood Press Monit     Publication Date:  2007 Feb 
Date Detail:
Created Date:  2007-02-16     Completed Date:  2007-04-27     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9606438     Medline TA:  Blood Press Monit     Country:  England    
Other Details:
Languages:  eng     Pagination:  45-9     Citation Subset:  IM    
Affiliation:
Department of Internal Medicine, Dişkapi Yildirim Beyazit Education and Research Hospital, Metropol Medical Center, Ankara, Turkey.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Blood Pressure Determination / instrumentation*
Female
Humans
Hypertension / diagnosis
Male
Middle Aged
Reproducibility of Results
Wrist / blood supply*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  An evaluation of the BD RT2000 reusable transducer system for invasive blood pressure monitoring.
Next Document:  Clinical assessment of the DINAMAP ProCare monitor in an adult population according to the British H...