VADoscopy: A Novel Intraoperative Technique to Evaluate HeartMate II Left Ventricular Assist Device Inflow Obstruction and Thrombosis.
MedLine Citation:
PMID:  24088904     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
With HeartMate II (HMII) implants increasing so has the frequency of device exchange. However, identifying inflow cannula obstruction, pump thrombosis, or outflow obstruction as the mechanism of pump dysfunction can be difficult. Echocardiography, CT angiogram, and cardiac catheterization are not definitive in determining the location of pump failure. Therefore, intraoperative examination is often necessary to confirm a diagnosis, requiring extensive dissection to visualize the entire system. We hypothesized a novel intraoperative technique, VADoscopy, can evaluate the inflow cannula for thrombus or pannus formation, and can help guide decision on which portion(s) of the HMII require replacement. Visualization of the inflow cannula can determine if either the pump itself or the pump along with the inflow cannula requires replacement, potentially limiting unnecessary dissection around the left ventricular apex and inflow cannula. A subxiphoid or subcostal incision exposes the pump. Patients are placed on cardiopulmonary bypass using the femoral vein and artery, after the outflow cannula is clamped. Once the pump is removed from the pocket, a 22 French 80 cm(Edwards Life Science, Irvine, CA) Fogarty balloon is advanced through the inflow cannula into the left ventricle and inflated to limit blood flow from the heart. A 5 French 30 cm flexible endoscope (Karl Starz Flex-X, Germany) is then placed into the inflow cannula and left ventricle to evaluate for the presence of thrombus, pannus, or debris. Six patients had HMII exchange with VADoscopy. In all patients, VADoscopy demonstrated no inflow cannula pannus or thrombus as the cause of pump dysfunction. Postoperatively there were no embolic events or evidence of reoccurring pump dysfunction suggesting an inflow cannula obstruction was not missed. VADoscopy is a novel and effective operative diagnostic modality to evaluate the inflow cannula within the HMII left ventricular assist device, limiting the amount of dissection, and potentially reducing the morbidity associated with HMII pump exchange.
Authors:
Allen Cheng; Michael F Swartz; H Todd Massey
Related Documents :
19833304 - Influence of abnormal glucose metabolism on coronary microvascular function after a rec...
10410004 - Reducing patient delay in seeking treatment for acute myocardial infarction.
20579854 - Heart rate on admission is an independent risk factor for poor cardiac function and in-...
16330914 - Prognostic value of thyroid hormone levels in acute myocardial infarction: just an epip...
23276444 - Refractory ventricular tachycardia in a long qt syndrome child successfully controlled ...
8625544 - Kawasaki syndrome: immunomodulatory benefit and potential toxin neutralization by intra...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2013-10-1
Journal Detail:
Title:  ASAIO journal (American Society for Artificial Internal Organs : 1992)     Volume:  -     ISSN:  1538-943X     ISO Abbreviation:  ASAIO J.     Publication Date:  2013 Oct 
Date Detail:
Created Date:  2013-10-3     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9204109     Medline TA:  ASAIO J     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
From the Department of Surgery, Division of Cardiothoracic Surgery, University of Rochester Medical Center, Rochester, NY.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Sedation Practice in Veno-Venous Extracorporeal Membrane Oxygenation: An International Survey.
Next Document:  Which Is Better: A Miniaturized Percutaneous Ventricular Assist Device or Extracorporeal Membrane Ox...