Using walker during walking:a pilot study for health elder.
MedLine Citation:
PMID:  22317023     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
Walker operation completely relies on the walker handle, however most marketed walkers possess two horizontal handles. Several researchers have suggested that horizontal handles might lead to wrist injury. Therefore, the purpose of this study is to assess the relevant design aspects of walker for elderly people. 28 elders participated in this study; when the experiment was started, subject walked on the tile for 3 meter distance twice by using walker. Data for analysis were selected at the corresponding wrist deviation and vertical force. The results showed that during walker using, the mean wrist deviation was greater than zero. The largest vertical force is significantly larger than the smallest one, and different wrist deviation occurred at three phases, the largest wrist deviation while raising walker is larger than the smallest one, however, no significant different was found between the largest and smallest wrist deviation while pressing walker. No significant correlation occurred between weight and wrist deviation. The correlation between weight and vertical force was significantly positive. With wrist deviation walker use may cause injury to upper-limb, however wrists remain in a neutral position during hand movement to prevent damage. The findings of this study should improve the design of walker handles to reduce the wrist deviations of users.
Authors:
Yeh Po-Chan; Leung Cherng-Yee
Related Documents :
22389423 - The effects of transverse rotation angle on compression and effective lever arm of pros...
22320053 - Future trends in the use of x-ray fluoroscopy for the measurement and modelling of join...
3499893 - Vestibular response to pseudorandom angular velocity input: progress report.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Work (Reading, Mass.)     Volume:  41     ISSN:  1875-9270     ISO Abbreviation:  Work     Publication Date:  2012 Jan 
Date Detail:
Created Date:  2012-02-09     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9204382     Medline TA:  Work     Country:  Netherlands    
Other Details:
Languages:  eng     Pagination:  2081-5     Citation Subset:  IM    
Affiliation:
The Graduate Institute of Design Science, Tatung University, 40, Chungshan N. Rd., Sec. 3 Taipei, 104, Taiwan.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  How user diversity and country of origin impact the readiness to adopt E-health technologies: an int...
Next Document:  An office chair to influence the sitting behavior of office workers.