Document Detail


Use of sonomicrometry and multidimensional scaling to determine the three-dimensional coordinates of multiple cardiac locations: feasibility and initial implementation.
MedLine Citation:
PMID:  7790015     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
We describe a new method which uses sonomicrometry and the statistical technique of multidimensional scaling (MDS) to measure the three-dimensional (3-D) coordinates of multiple cardiac locations. We refer to this new method as sonomicrometry array localization (SAL). The new method differs from standard sonomicrometry in that each piezoelectric transducer element is used as both transmitter and receiver and the set of intertransducer element distances is measured. MDS calculates the 3-D coordinates of each sonomicrometry transducer element from the set of intertransducer element distances. The feasibility of this new method was tested with mathematical simulations which demonstrated the ability of MDS to compensate for signal error and missing intertransducer element distances. We describe the design elements of a modified digitally controlled sonomicrometer in which a single transducer element can sequentially broadcast to as many as eight receiver elements. That design is used to validate SAL in a water bath and in ex vivo and living hearts. Correlation with caliper measurement in the water bath (y int. = 3.91 +/- 3.36 mm, slope = 1.04 +/- 0.05, r2 = 0.969 +/- 0.027) and with radiography in ex vivo (y int. = -0.87 +/- 0.92 mm, slope = 0.97 +/- 0.02, r2 = 0.960 +/- 0.023) and in vivo hearts (y int. = 2.98 +/- 2.59 mm, slope = 1.01 +/- 0.06, r2 = 0.953 +/- 0.031) was excellent. Sonomicrometry array localization is able to accurately measure the 3-D coordinates of multiple cardiac locations. It can potentially measure myocardial deformation and remodeling after ischemic or valvular injury.
Authors:
M B Ratcliffe; K B Gupta; J T Streicher; E B Savage; D K Bogen; L H Edmunds
Related Documents :
22682625 - Acute panmyelosis with myelofibrosis with evi1 amplification.
20725145 - Recent transposition of yabusame, a novel piggybac-like transposable element in the gen...
16453655 - Successive transposition explosions in drosophila melanogaster and reverse transpositio...
9037155 - Comparative analysis of the chromosomal and genomic organization of ty1-copia-like retr...
1539015 - Partitioning of the chicken genome by microcell hybridization.
9844605 - Cytogenetic changes in benign proliferative and nonproliferative lesions of the breast.
Publication Detail:
Type:  Comparative Study; In Vitro; Journal Article; Research Support, U.S. Gov't, P.H.S.    
Journal Detail:
Title:  IEEE transactions on bio-medical engineering     Volume:  42     ISSN:  0018-9294     ISO Abbreviation:  IEEE Trans Biomed Eng     Publication Date:  1995 Jun 
Date Detail:
Created Date:  1995-07-26     Completed Date:  1995-07-26     Revised Date:  2009-11-11    
Medline Journal Info:
Nlm Unique ID:  0012737     Medline TA:  IEEE Trans Biomed Eng     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  587-98     Citation Subset:  IM    
Affiliation:
Department of Surgery, School of Medicine, University of Pennsylvania, Philadelphia 19104, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Algorithms
Animals
Artifacts
Echocardiography / instrumentation,  methods*,  statistics & numerical data
Feasibility Studies
Microcomputers
Models, Structural
Normal Distribution
Reproducibility of Results
Sheep
Transducers
Grant Support
ID/Acronym/Agency:
HL-36308/HL/NHLBI NIH HHS

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A technique for measurement of the extent of spatial organization of atrial activation during atrial...
Next Document:  Action potentials of curved nerves in finite limbs.