Use of a pulse oximeter in an adult emergency department: impact on the number of arterial blood gas analyses ordered.
MedLine Citation:
PMID:  9554645     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
STUDY OBJECTIVES: To assess the impact of pulse oximetry (SpO2) on the indications and the number of arterial blood gas (ABG) levels ordered in an adult emergency department (ED). DESIGN: A prospective study during a 2-month period in 1993 with a pulse oximeter available and a comparison with the same period in 1992 without the oximeter. SETTING: An adult medical ED of a university hospital in France. PATIENTS: All patients who underwent ABG or SpO2 measurements. INTERVENTIONS: During the prospective study, residents ordered ABG or SpO2 measurements at their discretion. The reasons for their ordering were reviewed by two independent experts who determined whether their choice was justified. The data were compared with those for 184 consecutive patients who had ABG measurements in 1992. MEASUREMENTS AND RESULTS: The study included 152 patients. SpO2 alone was used in 33 patients; ABG levels were measured in 119 patients. The use of SpO2 did not result in the ordering of fewer useful ABG determinations. One hundred and five (88%) ABG measurements were justified. There were fewer unjustified ABG determinations in 1993 when the pulse oximeter was available than in 1992 when it was not (14 of 119 vs 54 of 184; p<0.001) mainly because fewer ABG determinations were ordered for miscellaneous nonrespiratory indications (13 of 119 vs 43 of 184; p<0.01). CONCLUSION: The availability of a pulse oximeter did not affect the ordering of useful ABG measurements but allowed a significant reduction of unjustified ABG measurements. Substantial cost savings could be achieved by using SpO2 in an ED.
Authors:
G Le Bourdellès; P Estagnasié; F Lenoir; P Brun; D Dreyfuss
Related Documents :
8214545 - End-tidal oxygen measurement compared with patient factor assessment for determining pr...
2719205 - Pulse oximetry in methaemoglobinaemia. failure to detect low oxygen saturation.
20407405 - Extent and magnitude of catecholamine surge in pediatric burned patients.
2635875 - Pulse oximetry in the recovery room.
20887695 - Trichoscan as a method to determine hair root pattern in patients with scalp psoriasis.
21507565 - A validation study of the chinese wearing off questionnaire 9-symptom for parkinson's d...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Chest     Volume:  113     ISSN:  0012-3692     ISO Abbreviation:  Chest     Publication Date:  1998 Apr 
Date Detail:
Created Date:  1998-05-04     Completed Date:  1998-05-04     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  0231335     Medline TA:  Chest     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  1042-7     Citation Subset:  AIM; IM    
Affiliation:
Service de Réanimation Médicale, Hôpital Louis Mourier, Colombes, France.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Blood Gas Analysis / utilization*
Cost Savings
Emergency Service, Hospital / economics,  statistics & numerical data*
Female
France
Hospital Bed Capacity, 300 to 499
Hospital Costs
Hospitals, University / economics
Humans
Male
Middle Aged
Oximetry / economics,  utilization*
Prospective Studies
Respiratory Tract Diseases / diagnosis*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Transbronchial lung biopsy: can specimen quality be predicted at the time of biopsy?
Next Document:  Right ventricular end-diastolic volume as a predictor of the hemodynamic response to a fluid challen...