Document Detail


Use of non-invasive finger blood pressure monitoring in the estimation of aortic pressure at rest and during the Mueller manoeuvre.
MedLine Citation:
PMID:  1424480     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The aim of this investigation was to evaluate whether reliable estimates of aortic pressure can be derived using non-invasive finger blood pressure monitoring. Finger blood pressure (Ohmeda 2300 Finapres device; Finapres, Englewood, CO) was compared with simultaneous ascending aortic pressure measured with a catheter-transducer system both at rest and during acute negative intrathoracic pressure (the Mueller manoeuvre). Thirty-eight patients aged 17-73 years were studied. All were undergoing routine diagnostic or therapeutic cardiac catheterization. Beat-to-beat values of systolic, diastolic and mean non-invasive finger and invasive aortic blood pressure were measured at rest and factors which might have an influence on the difference between methods were examined. The mean finger-aortic difference was +5 +/- 14 mmHg for systolic, -2 +/- 7 mmHg for diastolic, -5 +/- 8 mmHg for mean and +6 +/- 13 mmHg for pulse pressure. In multivariate linear regression analysis, the difference in systolic pressure was related to aortic systolic pressure (standardized coefficient beta = -0.33, P = 0.01), heart rate (beta = 0.49, P < 0.000), age (beta = -0.29, P < 0.025) and height (beta = 0.40, P < 0.005). The linear regression equations to derive resting aortic pressures from the non-invasive finger pressure readings had correlation coefficients between 0.83 and 0.87 and standard errors of estimate between 6 and 14 mmHg. During the Mueller manoeuvre, Finapres reproduced average pressure changes reliably compared with intra-aortic pressure. Due to moderate inter-individual variation in the finger-aortic differences the correlation coefficients ranged from 0.83 to 0.93 and the standard errors of estimate from 3 to 6 mmHg. Non-invasive finger blood pressure monitoring could be used to estimate central aortic mean and diastolic blood pressure fairly reliably at rest, but with respect to systolic pressure the variance in finger-aortic difference was marked. The average intra-aortic pressure changes caused by the Mueller manoeuvre were reliably reproduced by the Finapres device.
Authors:
J Virolainen
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Clinical physiology (Oxford, England)     Volume:  12     ISSN:  0144-5979     ISO Abbreviation:  Clin Physiol     Publication Date:  1992 Nov 
Date Detail:
Created Date:  1992-12-14     Completed Date:  1992-12-14     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  8309768     Medline TA:  Clin Physiol     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  619-28     Citation Subset:  IM    
Affiliation:
First Department of Medicine, Helsinki University Central Hospital, Finland.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adolescent
Adult
Aged
Aorta / physiology*
Blood Pressure Monitors*
Female
Fingers / blood supply*
Humans
Male
Middle Aged
Respiration*
Rest

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Early exercise thallium-201 single photon emission computed tomography in unstable angina: a prospec...