Use of the elective replacement indicator in predicting time of automatic implantable cardioverter-defibrillator battery depletion.
MedLine Citation:
PMID:  2478970     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The elective replacement indicator (ERI) of an automatic implantable cardioverter-defibrillator (AICD) is intended to be utilized as strict criteria for the appropriate timing of pulse generator replacement. The manufacturer's newest recommendations suggest replacement within 3 months post-ERI attainment and this applies to both AID-B units and the latest Ventak models currently being implanted with expectations or increased battery longevity. Twelve patients with the AID-B model were prospectively evaluated in regard to (a) time from attainment of ERI to generator exchange and (b) total battery life with respect to the presence or absence of spontaneous discharges. In the overall group, the ERI was reached at 18.9 +/- 3.9 months (mean +/- standard deviation). The time from ERI attainment to generator exchange due to battery depletion was 8.1 +/- 5.1 months, and total battery life was 27.3 +/- 3.1 months. In the group with spontaneous discharges, the duration of time (months) post-ERI to generator exchange was 5.7 +/- 2.6 but was 11.4 +/- 6.1 in the others (P = 0.052); battery life was 25.7 +/- 2.4 and 29.4 +/- 2.7, respectively (P = 0.03). We conclude that the current ERI recommendation seems overly conservative in planning generator exchange for patients without the occurrence of spontaneous discharges and appropriate for patients with such discharges.
Authors:
D Aaarons; M Mower; E Veltri
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Pacing and clinical electrophysiology : PACE     Volume:  12     ISSN:  0147-8389     ISO Abbreviation:  Pacing Clin Electrophysiol     Publication Date:  1989 Nov 
Date Detail:
Created Date:  1989-12-18     Completed Date:  1989-12-18     Revised Date:  2005-11-17    
Medline Journal Info:
Nlm Unique ID:  7803944     Medline TA:  Pacing Clin Electrophysiol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  1724-8     Citation Subset:  IM    
Affiliation:
Department of Medicine, Sinai Hospital of Baltimore, Maryland 21215.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Electric Countershock / instrumentation*
Electric Power Supplies*
Electrodes, Implanted
Female
Follow-Up Studies
Humans
Male
Middle Aged
Prospective Studies
Tachycardia / therapy*
Time Factors
Ventricular Fibrillation / therapy*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Upper limit ventricular stimulation in respiratory rate responsive pacing due to electrocautery.
Next Document:  Undersensing of P waves in the presence of an adequate P wave due to automatic postventricular atria...