Document Detail

Use of Contegra conduit reinforced with Goretex as a modified left Blalock-Taussig shunt.
MedLine Citation:
PMID:  20824594     Owner:  NLM     Status:  MEDLINE    
This is the first report of the construction of a modified Blalock-Taussig shunt using a Contegra conduit reinforced with Goretex in a 4-year-old boy. The patient had a complex cardiac history with a primary diagnosis of pulmonary atresia, hypoplastic right ventricle (RV) and RV-coronary artery fistula.
H A Vohra; R Whistance; A Gulati; M P Haw
Related Documents :
21607674 - Giant coronary aneurysms: three-dimensional reconstruction.
22236394 - Copeptin in aneurysmal subarachnoid hemorrhage.
21961014 - One-stage combined thoracic ancient schwannomas total removal and coronary artery bypass.
21030924 - Giant saccular aneurysm of coronary arteriovenous fistula to the main pulmonary artery:...
8993814 - Intravascular ultrasound identification of stent entrapment in vivo with in vitro confi...
11486194 - Anomalous origin of the left coronary artery from the pulmonary artery: successful surg...
Publication Detail:
Type:  Case Reports; Journal Article     Date:  2010-09-07
Journal Detail:
Title:  The Thoracic and cardiovascular surgeon     Volume:  58     ISSN:  1439-1902     ISO Abbreviation:  Thorac Cardiovasc Surg     Publication Date:  2010 Sep 
Date Detail:
Created Date:  2010-09-08     Completed Date:  2010-12-28     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7903387     Medline TA:  Thorac Cardiovasc Surg     Country:  Germany    
Other Details:
Languages:  eng     Pagination:  366-7     Citation Subset:  IM    
Copyright Information:
Georg Thieme Verlag KG Stuttgart, New York.
Department of Cardiac Surgery, Wessex Cardiothoracic Centre, Southampton, United Kingdom.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Abnormalities, Multiple / surgery*
Anticoagulants / therapeutic use
Blalock-Taussig Procedure / instrumentation*
Blood Vessel Prosthesis*
Blood Vessel Prosthesis Implantation / instrumentation*
Child, Preschool
Heart Defects, Congenital / surgery*
Prosthesis Design
Treatment Outcome
Reg. No./Substance:
0/Anticoagulants; 9002-84-0/Polytetrafluoroethylene

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Previous Document:  Right ventricular outflow obstruction of the patient with biventricular non-compaction.
Next Document:  Giant congenital coronary aneurysm of the left anterior descending artery.