| On the Use of In Vivo Measured Flow Rates as Boundary Conditions for Image-Based Hemodynamic Models of the Human Aorta: Implications for Indicators of Abnormal Flow. | |
| | |
MedLine Citation:
|
PMID: 22009313 Owner: NLM Status: Publisher |
Abstract/OtherAbstract:
|
The purpose of this study is to investigate how the imposition of personalized, non-invasively measured blood flow rates as boundary conditions (BCs) influences image-based computational hemodynamic studies in the human aorta. We extracted from 4D phase-contrast MRI acquisitions of a healthy human (1) the geometry of the thoracic aorta with supra-aortic arteries and (2) flow rate waveforms at all boundaries. Flow simulations were carried out, and the implications that the imposition of different BC schemes based on the measured flow rates have on wall shear stress (WSS)-based indicators of abnormal flow were analyzed. Our results show that both the flow rate repartition among the multiple outlets of the aorta and the distribution and magnitude of the WSS-based indicators are strongly influenced by the adopted BC strategy. Keeping as reference hemodynamic model the one where the applied BC scheme allowed to obtain a satisfactory agreement between the computed and the measured flow rate waveforms, differences in WSS-based indicators up to 49% were observed when the other BC strategies were applied. In conclusion, we demonstrate that in subject-specific computational hemodynamics models of the human aorta the imposition of BC settings based on non-invasively measured flow rate waveforms influences indicators of abnormal flow to a large extent. Hence, a BCs set-up assuring realistic, subject-specific instantaneous flow rate distribution must be applied when BCs such as flow rates are prescribed. |
| | |
Authors:
|
D Gallo; G De Santis; F Negri; D Tresoldi; R Ponzini; D Massai; M A Deriu; P Segers; B Verhegghe; G Rizzo; U Morbiducci |
Related Documents
:
|
8240923 - Tissue distribution of bupivacaine enantiomers in sheep. 8046623 - Distribution and tissue uptake of poly(ethylene glycol) with different molecular weight... 8198273 - Increased cerebral and decreased femoral artery blood flow velocities during direct lar... |
Publication Detail:
|
Type: JOURNAL ARTICLE Date: 2011-10-19 |
Journal Detail:
|
Title: Annals of biomedical engineering Volume: - ISSN: 1521-6047 ISO Abbreviation: - Publication Date: 2011 Oct |
Date Detail:
|
Created Date: 2011-10-19 Completed Date: - Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 0361512 Medline TA: Ann Biomed Eng Country: - |
Other Details:
|
Languages: ENG Pagination: - Citation Subset: - |
Affiliation:
|
Department of Mechanics, Politecnico di Torino, Corso Duca degli Abruzzi, 24, 10129, Turin, Italy, diego.gallo@polito.it. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
|
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Adaptive Filter Based Two-Probe Noise Suppression System for Transient Evoked Otoacoustic Emission D...
Next Document: The Effect of Magnesium Ion Concentration on the Fibrocartilage Regeneration Potential of Goat Costa...