Document Detail


Is Use of a Continuous Autotransfusion System Beneficial in Emergency Abdominal Aortic Aneursym (AAA) Surgery?
MedLine Citation:
PMID:  21549916     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
BACKGROUND: Allogeneic blood products have become a limited and expensive resource. The Continuous Autotransfusion System (CATS) has been promoted as a method for reducing the need for allogeneic blood transfusion. This study was undertaken to ascertain whether the use of CATS in emergency open AAA surgery has any benefits.
METHODS: This is a retrospective study of all patients undergoing emergency open AAA surgery in our center during a 5-year period (between July 2004 and July 2009). Patients were identified from a prospectively maintained vascular database, and data were obtained from patient records.
RESULTS: CATS was used in 69 emergency open AAA repairs. The median total blood loss was 3,500 mL (range: 751-13,796 mL) but the median volume of packed red blood cells produced by CATS was only 493 mL (∼2 U). An average of 7 U (range: 0-19 U) of bank blood was still used despite the availability of CATS. The mean hemoglobin 24 hours postoperatively was 10.3 g/dL (6.4-14.1) with a hematocrit of 0.30.
CONCLUSION: The use of CATS in emergency AAA surgery does not seem to reduce the use of allogeneic blood transfusion. This may be because of over transfusion, as reflected by relatively high postoperative hemoglobin levels.
Authors:
C N Brown; C Hakim; R D Sayers; N J M London; A Nasim
Related Documents :
20802906 - Correlation between right atrial venous blood gasometry and cardiac index in cardiac su...
3494826 - Bleeding rates necessary for detecting acute gastrointestinal bleeding with technetium-...
6354156 - Measurement of blood flow in the dental pulp of dogs with the 133xenon washout method.
20943316 - Modeling and evaluation on removal of hexavalent chromium from aqueous systems using fi...
9098256 - Measurement of the resistance to fluid flow within the lacrimal outflow system.
19427756 - Insight in microcirculation and histomorphology during burn shock treatment using in vi...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Annals of vascular surgery     Volume:  25     ISSN:  1615-5947     ISO Abbreviation:  Ann Vasc Surg     Publication Date:  2011 May 
Date Detail:
Created Date:  2011-05-09     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8703941     Medline TA:  Ann Vasc Surg     Country:  United States    
Other Details:
Languages:  eng     Pagination:  481-4     Citation Subset:  IM    
Copyright Information:
Copyright © 2011 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.
Affiliation:
Department of Vascular and Endovascular Surgery, Leicester Royal Infirmary, Leicester, UK.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Traumatic aortic rupture: 30 years of experience.
Next Document:  Physiologic component of the estimation of physiologic ability and surgical stress scoring system as...