| Use of the Angiojet catheter to remove plaque outside a neuroprotection filter during carotid artery stenting. | |
| | |
MedLine Citation:
|
PMID: 19769814 Owner: NLM Status: MEDLINE |
Abstract/OtherAbstract:
|
Carotid protection devices (CPD) during carotid artery stenting reduce the risk of cerebral embolization. The presence of debris outside the filter presents a problem as the material may be plaque or thrombus. We report a case that required the use of the Angiojet catheter to remove debris outside the CPD. |
| | |
Authors:
|
Eric D Wellons; Paul V Kochupura; Allison B Burkett; Daniel T McDevitt; David Rosenthal |
Related Documents
:
|
6600354 - Carotid atherosclerosis: high-resolution real-time sonography correlated with angiography. 20329964 - Visualizing the functional properties of life-threatening atherosclerotic plaques using... 9006284 - Are soft echoes really soft? intravascular ultrasound assessment of mechanical properti... 19161364 - Atherosclerosis is associated with plasminogen activator inhibitor type-1 in chronic ha... 22639684 - Posterior inferior cerebellar artery aneurysms: anatomical variations and surgical stra... 7893094 - Pulmonary failure following lower torso ischemia: clinical evidence for a remote effect... |
Publication Detail:
|
Type: Case Reports; Journal Article |
Journal Detail:
|
Title: Vascular Volume: 17 ISSN: 1708-5381 ISO Abbreviation: Vascular Publication Date: 2009 Sep-Oct |
Date Detail:
|
Created Date: 2009-09-22 Completed Date: 2009-11-17 Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 101196722 Medline TA: Vascular Country: Canada |
Other Details:
|
Languages: eng Pagination: 300-2 Citation Subset: IM |
Affiliation:
|
Department of Vascular Surgery, Atlanta Medical Center, Atlanta, GA, USA. ewellons@gmail.com |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Angioplasty, Balloon
/
adverse effects* Carotid Artery, Common / radiography* Carotid Stenosis / radiography, therapy* Filtration / instrumentation Humans Intracranial Embolism / etiology, prevention & control* Male Middle Aged Stents* Suction / instrumentation |
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Isolated superficial temporal artery dissection masquerading as giant cell arteritis.
Next Document: Tubercular cervical adenitis: clinicopathologic analysis of 180 cases.