Document Detail


Use of the Angiojet catheter to remove plaque outside a neuroprotection filter during carotid artery stenting.
MedLine Citation:
PMID:  19769814     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Carotid protection devices (CPD) during carotid artery stenting reduce the risk of cerebral embolization. The presence of debris outside the filter presents a problem as the material may be plaque or thrombus. We report a case that required the use of the Angiojet catheter to remove debris outside the CPD.
Authors:
Eric D Wellons; Paul V Kochupura; Allison B Burkett; Daniel T McDevitt; David Rosenthal
Related Documents :
6600354 - Carotid atherosclerosis: high-resolution real-time sonography correlated with angiography.
20329964 - Visualizing the functional properties of life-threatening atherosclerotic plaques using...
9006284 - Are soft echoes really soft? intravascular ultrasound assessment of mechanical properti...
19161364 - Atherosclerosis is associated with plasminogen activator inhibitor type-1 in chronic ha...
22639684 - Posterior inferior cerebellar artery aneurysms: anatomical variations and surgical stra...
7893094 - Pulmonary failure following lower torso ischemia: clinical evidence for a remote effect...
Publication Detail:
Type:  Case Reports; Journal Article    
Journal Detail:
Title:  Vascular     Volume:  17     ISSN:  1708-5381     ISO Abbreviation:  Vascular     Publication Date:    2009 Sep-Oct
Date Detail:
Created Date:  2009-09-22     Completed Date:  2009-11-17     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101196722     Medline TA:  Vascular     Country:  Canada    
Other Details:
Languages:  eng     Pagination:  300-2     Citation Subset:  IM    
Affiliation:
Department of Vascular Surgery, Atlanta Medical Center, Atlanta, GA, USA. ewellons@gmail.com
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Angioplasty, Balloon / adverse effects*
Carotid Artery, Common / radiography*
Carotid Stenosis / radiography,  therapy*
Filtration / instrumentation
Humans
Intracranial Embolism / etiology,  prevention & control*
Male
Middle Aged
Stents*
Suction / instrumentation