BACKGROUND: Positive end-expiratory pressure (PEEP) may reduce cardiac output and total hepatic blood flow after liver transplantation. Pulse pressure variation is useful in predicting the PEEP-induced decrease in cardiac output. The aim of the study was to examine the relationships between stroke volume variations (SVV) obtained with the Vigileo monitor (Edwards Lifesciences, Irvine, CA), and the hemodynamic effects of PEEP. METHODS: Over 2 yr, patients presenting an acute lung injury or an acute respiratory distress syndrome in the 72 h after liver transplantation were prospectively enrolled. Patients were monitored with a pulmonary artery catheter (stroke volume) and with the Vigileo system (stroke volume and SVV). Measurements were performed in duplicate, first during zero end-expiratory pressure and then 10 min after the addition of 10 cm H2O PEEP. RESULTS: Twenty-six patients were included. Six patients were excluded from analysis. On PEEP, SVV and pulse pressure variation increased significantly and stroke volume decreased significantly. PEEP-induced changes in stroke volume measured by pulmonary artery catheter were significantly correlated with SVV (r = 0.69; P < 0.001) and pulse pressure variation on zero end-expiratory pressure (r = 0.66, P < 0.001). PEEP-induced decrease in stroke volume measured by pulmonary artery catheter > or = 15% was predicted by an SVV > 7% (sensitivity = 100%, specificity = 80%) and by a pulse pressure variation > 8% (sensitivity = 80%, specificity = 100%). PEEP-induced changes in stroke volume measured by pulmonary artery catheter and Vigileo device were correlated (r = 0.51, P < 0.005). CONCLUSIONS: SVV obtained with Vigileo monitor is useful to predict decrease in stroke volume induced by PEEP. Moreover, this device is able to track changes in stroke volume induced by PEEP.
Authors:
Matthieu Biais; Karine Nouette-Gaulain; Alice Quinart; Stéphanie Roullet; Philippe Revel; François Sztark
Related Documents :
373468 - Effect of positive end-expiratory pressure on ventricular function in dogs.
10435478 - Comparison of peak expiratory flows and fev1 in assessing immediate asthmatic reactions...
10988208 - Effects of fiberoptic bronchoscopy during mechanical ventilation in a lung model.
7007608 - The relationship between peak inspiratory pressure and positive end expiratory pressure...
15036568 - Sustained perimacular vascular and visual response to topical beta blockers in normal h...
23032138 - The effect of coffee consumption on blood pressure and the development of hypertension:...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Anesthesiology     Volume:  111     ISSN:  1528-1175     ISO Abbreviation:  Anesthesiology     Publication Date:  2009 Oct 
Date Detail:
Created Date:  2009-12-23     Completed Date:  2010-01-12     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  1300217     Medline TA:  Anesthesiology     Country:  United States    
Other Details:
Languages:  eng     Pagination:  855-62     Citation Subset:  AIM; IM    
Affiliation:
Department of Anesthesiology and Intensive Care Medicine, Centre Hospitalier Universitaire de Bordeaux, Place Amélie Raba Léon, Bordeaux, France. matthieu.biais@chu-bordeaux.fr
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Blood Pressure / physiology
Catheterization
Echocardiography, Doppler
Endpoint Determination
Female
Hemodynamics / physiology*
Humans
Liver Transplantation / adverse effects*
Lung Diseases / etiology,  physiopathology*,  ultrasonography
Male
Middle Aged
Monitoring, Intraoperative
Positive-Pressure Respiration*
Postoperative Complications / physiopathology*
Predictive Value of Tests
Pulmonary Artery / physiology
Respiration, Artificial
Respiratory Distress Syndrome, Adult / etiology,  physiopathology*,  ultrasonography
Stroke Volume / physiology*