Two-frequency impedance plethysmograph: real and imaginary parts.
MedLine Citation:
PMID:  2325449     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
A four-channel impedance plethysmograph has been designed. Impedance signals are obtained at two frequencies by measuring both real and imaginary parts. Particular attention has been paid to the sine wave generation circuits that provide system versatility. The required phase-sensitive demodulation is achieved by means of analogue multiplexers. Results show that there are significant variations in the thoracic equivalent capacitance related to respiration and that there is an increased sensitivity to cardiac activity at low frequencies.
Authors:
A Lozano; J Rosell; R Pallás-Areny
Related Documents :
23599249 - A pollinators' eye view of a shelter mimicry system.
2935519 - Forced oscillatory impedance of the respiratory system at low frequencies.
21116679 - Fluctuation and response in biology.
23755019 - Echolocation in oilbirds and swiftlets.
23464049 - Auditory masking patterns in bottlenose dolphins (tursiops truncatus) with natural, ant...
10631659 - Excitation frequencies of ions confined in a quadrupole field with quadrupole excitation.
18021469 - Value of serum free light chain testing for the diagnosis and monitoring of monoclonal ...
23567569 - High-contrast dark resonances with linearly polarized light on the d1 line of alkali at...
3702379 - Speech waveform perturbation analysis: a perceptual-acoustical comparison of seven meas...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Medical & biological engineering & computing     Volume:  28     ISSN:  0140-0118     ISO Abbreviation:  Med Biol Eng Comput     Publication Date:  1990 Jan 
Date Detail:
Created Date:  1990-05-24     Completed Date:  1990-05-24     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  7704869     Medline TA:  Med Biol Eng Comput     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  38-42     Citation Subset:  IM    
Affiliation:
Divisió de Instrumentació i Bioenginyeria, ETSE Telecomunicació, Barcelona, Spain.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Analog-Digital Conversion
Electricity
Heart / physiology
Humans
Plethysmography, Impedance / instrumentation*