Transtibial prosthetic socket pistoning: Static evaluation of Seal-In(®) X5 and Dermo(®) Liner using motion analysis system.
MedLine Citation:
PMID:  21794965     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: The method of attachment of prosthesis to the residual limb (suspension) and socket fitting is a critical issue in the process of providing an amputee with prosthesis. Different suspension methods try to minimize the pistoning movement inside the socket. The Seal-In(®) X5 and Dermo(®) Liner by Ossur are new suspension liners that intend to reduce pistoning between the socket and liner. Since the effects of these new liners on suspension are unclear, the objective of this study was to compare the pistoning effect of Seal-In(®) X5 and Dermo(®) Liner by using Vicon Motion System. METHODS: Six transtibial amputees, using both the Iceross Seal-In(®) X5 and the Iceross Dermo(®) Liner, participated in the study. The vertical displacement (pistoning) was measured between the liner and socket in single limb support on the prosthetic limb (full-weight bearing), double limb support (semi-weight bearing), and non-weight bearing on the prosthetic limb, and also under three static vertical loading conditions (30N, 60N, and 90N). FINDINGS: The results demonstrated that the pistoning within the socket when Seal-In(®) X5 was used, decreased by 71% in comparison to the Iceross Dermo(®) Liner. In addition, a significant difference between the two liners under different static conditions was found (p<0.05). INTERPRETATION: Participants needed to put in extra effort for donning and doffing the prosthesis with Seal-In(®) X5; however, this type of liner provided less pistoning. The new approach that uses the motion analysis system in this study might be an alternative for measuring the pistoning effect in the prosthetic socket.
Authors:
H Gholizadeh; N A Abu Osman; M Kamyab; A Eshraghi; W A B Wan Abas; M N Azam
Related Documents :
20881285 - High-resolution multifocal pupillographic objective perimetry in glaucoma.
22519595 - Increased plasma light levels in patients with atopic dermatitis.
22749285 - Photocontrol of bud burst involves gibberellin biosynthesis in rosa sp.
16812585 - Nonhumans have not yet shown stimulus equivalence.
2704565 - Frequency analysis of electromyographically measured covert speech behavior.
11008135 - What limits simultaneous discrimination accuracy?
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-7-25
Journal Detail:
Title:  Clinical biomechanics (Bristol, Avon)     Volume:  -     ISSN:  1879-1271     ISO Abbreviation:  -     Publication Date:  2011 Jul 
Date Detail:
Created Date:  2011-7-28     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8611877     Medline TA:  Clin Biomech (Bristol, Avon)     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2011 Elsevier Ltd. All rights reserved.
Affiliation:
Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Malaysia.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Wound healing differences between Yorkshire and red Duroc porcine medial collateral ligaments identi...
Next Document:  Approach to the Evaluation of a Patient With an Increased Serum Osmolal Gap and High-Anion-Gap Metab...