Document Detail

Transmural "Scar-to-Scar" Reentrant Ventricular Tachycardia.
Jump to Full Text
MedLine Citation:
PMID:  24482562     Owner:  NLM     Status:  PubMed-not-MEDLINE    
Abstract/OtherAbstract:
We describe a scar-related reentrant ventricular tachycardia circuit with a proximal segment in an endocardial basal septal scar and an exit in a region of slow conduction in a non-overlapping region of epicardial basal lateral scar. The 12-lead EKG demonstrates criteria for a basal lateral epicardial VT, however the same morphology could be produced with a longer stim-latency with pace mapping or VT induction from the endocardial septal region of scar. A significant segment of myocardium demonstrated no endocardial or epicardial scar on electroanatomic mapping, suggesting the presence of a mid-myocardial isthmus. Further evidence was provided by assessment of unipolar settings. The epicardial VT that initially appeared to originate from the basal lateral epicardial region, was successfully treated with radiofrequency ablation of the lateral aspect of the endocardial septal scar.
Authors:
Jason S Bradfield; Roderick Tung; Kalyanam Shivkumar
Publication Detail:
Type:  Journal Article     Date:  2013-11-15
Journal Detail:
Title:  Indian pacing and electrophysiology journal     Volume:  13     ISSN:  0972-6292     ISO Abbreviation:  Indian Pacing Electrophysiol J     Publication Date:  2013 Nov 
Date Detail:
Created Date:  2014-01-31     Completed Date:  2014-01-31     Revised Date:  2014-02-03    
Medline Journal Info:
Nlm Unique ID:  101157207     Medline TA:  Indian Pacing Electrophysiol J     Country:  India    
Other Details:
Languages:  eng     Pagination:  212-6     Citation Subset:  -    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Full Text
Journal Information
Journal ID (nlm-ta): Indian Pacing Electrophysiol J
Journal ID (iso-abbrev): Indian Pacing Electrophysiol J
Journal ID (publisher-id): Indian Pacing Electrophysiol J
ISSN: 0972-6292
Publisher: Indian Heart Rhythm Society
Article Information
Download PDF
Copyright: © 2013 Bradfield et al.
open-access:
collection publication date: Season: Nov-Dec Year: 2013
Electronic publication date: Day: 15 Month: 11 Year: 2013
Volume: 13 Issue: 6
First Page: 212 Last Page: 216
PubMed Id: 24482562
ID: 3876580
Publisher Id: ipej130212-00

Transmural "Scar-to-Scar" Reentrant Ventricular Tachycardia
Jason S Bradfield, MD
Roderick Tung, MD
Kalyanam Shivkumar, MD, PhD
UCLA Cardiac Arrhythmia Center, David Geffen School of Medicine at UCLA, Los Angeles, CA
Correspondence: Address for correspondence: Jason Bradfield, MD, UCLA Cardiac Arrhythmia Center, Ronald Reagan UCLA Medical Center, David Geffen School of Medicine at UCLA, 100 Medical Plaza, suite 660, Los Angeles CA 90095. JBradfield@mednet.ucla.edu

Case

We present a 46 year-old man with a history of non-ischemic cardiomyopathy (CM), likely of familial origin, status-post implantable cardioverter-defibrillator (ICD) implantation who was transferred to our center after presenting with ventricular tachycardia (VT) storm and recurrent ICD shocks for monomorphic VT, with a rate between 165-175 beats-per-minute, despite therapy with antiarrhythmic medications.

The patient underwent endocardial and epicardial mapping as is the protocol at our institution for any patient with a non-ischemic cause of their CM. Endocardial and epicardial electroanatomic maps (EAM) were obtained with a Carto 3 system (Biosense Webster, Diamond Bar, CA). (Figure 1c)

Monomorphic VT was induced with double extrastimuli testing. Standard 12-lead EKG morphology demonstrated a VT with a right bundle branch block pattern, V5 transition and inferior axis at a rate of 170 beats-per-minute (Figure 1f). The EKG characteristics met criteria for an epicardial exit based on a pseudo-delta wave >75ms and an MDI >0.59. [1] The VT was not hemodynamically tolerated and therefore a substrate based approach targeting late potentials and utilizing pace mapping was required.

An excellent pace-map could be produced from the basal lateral epicardial surface (Figure 1a) with a short stim-QRS latency of 30 ms, which was 16% of the tachycardia cycle length (TCL) consistent with an exit site. No late potentials (Figure 1b) were seen on the epicardial surface and therefore we proceeded with trans-septal catheterization and voltage mapping of the left ventricular endocardium.

Interestingly, at a late potential site (Figure 1d) within the endocardial basal septal scar, a similarly well matched pace-map of the tachycardia was seen with a longer stim-QRS latency of 115 ms, which was 60% of the TCL consistent with a proximal isthmus site. (Figure 1e) Additionally, as recently described by our group, a pace map induction (PMI) and multiple exits sites (MES) were seen from a region of slow conduction within the endocardial basal septal scar. [2] There was no endocardial basal lateral scar to correspond to the epicardial basal lateral scar and further there was a larger region of the anterior wall between the two regions of scar that had no discernable scar on the endocardial or epicardial surfaces. (Figure 2 and 3) Assessment of unipolar setting based on the work of Hutchinson and colleagues [3] suggested the presence of a region of abnormal voltage that may provide an intramural connection between the endocardial and epicardial scars. (Figure 3)

Radiofrequency ablation of the lateral aspect of the septal endocardial scar at sites of late and fractionated potentials was undertaken. After ablation of this region the clinical tachycardia was non-inducible. The patient was free of VT at greater than 9 months follow-up off of antiarrhythmic medications.


Discussion

The above findings demonstrate that the VT exit site was the basal lateral epicardium. The findings of no corresponding endocardial basal lateral scar with endocardial septal pace-maps that were matches to the epicardial pace-maps at a lateral site, in combination with a VT that could be induced from the endocardial septal region with a PMI suggests a mid-myocardial connection between the two scar regions that was not adequately visualized with standard EAM system settings.

This is the first description in the literature we are aware of demonstrating a VT circuit that likely required a bridging mid-myocardial segment for non-overlapping regions of scar on the endocardium and epicardium. While current practice and available mapping techniques lead electrophysiologists to label VT as having an endocardial or epicardial origin, myocardial scar formation does not follow an either/or pattern. Rather many, if not most, myocardial scars that predispose to reentry likely involve a complex three-dimensional substrate that may include the endocardium, mid-myocadium and epicardium. This finding has been reported in a canine model [4]. However, there is little data regarding this concept in humans but the limited available data suggests that mid-myocardial circuits may be even more common in a non-ischemic CM population.

Anter and colleages [5] reported their experience with surgical ablation after failed percutaneous ablation. They report that at least 4/8 patients in their series had mid-myocardial scar seen on cMRI and that when detailed electroanatomic maps were obtained there was no corresponding scar seen at the corresponding endocardial or epicardial sites. Further work has demonstrated that cardiac MRI and EAM systems with appropriate settings can demonstrate extension of scar vital to arrhythmia origin that are distant from the endocardial surface, including intramural scar, and that unipolar voltage settings may be of particular use in this setting. However, much of this work was done in ischemic CM, but data on the non-ischemic CM patient population is beginning to emerge and needs further study.

These early studies and this case raises the importance of a complete electroanatomic map with pacemapping used as an adjunct technique for scar-related reentry, especially in a situation where the initially proposed exit site of the tachycardia demonstrates no late potential activity in a hemodynamically untolerated VT.

Lastly, this case illustrates that 12-lead morphology is only predictive of the exit site of a reentrant circuit. There are likely many VT morphologies that indicate the need for epicardial mapping and ablation with subendocardial or intramural isthmuses and vice versa.

The use of pace-mapping and not entrainment mapping is a limitation of this manuscript. Stim-QRS latency during pacing is not necessarily synonymous with Stim-QRS during entrainment. However, the authors interpret the longer stim-QRS latency to be similarly indicative of progressive distance from the exit site and evidence that in this case there was a single preferential exit site toward the lateral epicardium.


References
Valles E,et al. ECG criteria to identify epicardial ventricular tachycardia in nonischemic cardiomyopathyCirculation Arrhythmia and electrophysiologyYear: 201036320008307
Tung R,et al. Functional pace-mapping responses for identification of targets for catheter ablation of scar-mediated ventricular tachycardiaCirculation Arrhythmia and electrophysiologyYear: 2012526422333344
Hutchinson MD,et al. Endocardial unipolar voltage mapping to detect epicardial ventricular tachycardia substrate in patients with nonischemic left ventricular cardiomyopathyCirculation Arrhythmia and electrophysiologyYear: 201144921131557
Garan H,et al. Endocardial, intramural, and epicardial activation patterns during sustained monomorphic ventricular tachycardia in late canine myocardial infarctionCirculation researchYear: 1987608793594759
Anter E,et al. Surgical ablation of refractory ventricular tachycardia in patients with nonischemic cardiomyopathyCirculation Arrhythmia and electrophysiologyYear: 2011449421673018

Article Categories:
  • Case Report

Keywords: Reentrant Ventricular Tachycardia, Transmural Scar.

Previous Document:  Randomized Prospective Comparison of Two Protocols for Head-up Tilt Testing in Patients with Normal ...