Transient drifts between Finapres and continuous intra-aortic measurements of blood pressure.
MedLine Citation:
PMID:  18004105     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVES: The accuracy of noninvasive measurements of arterial blood pressure (BP), in comparison to intra-arterial recordings, is normally quantified by the bias, which is usually assumed to be a constant parameter. We tested the hypothesis that continuous beat-to-beat differences are not random and aimed to describe the temporal pattern of any transient drifts. METHODS: Forty participants were studied after undergoing elective cardiac catheterization. Continuous recordings of noninvasive finger BP (Finapres), intra-aortic BP (Millar catheter-tip transducer) and electrocardiogram were carried out for two periods of 10 min each. The mean of continuous beat-to-beat differences between the two BP sources was removed for the entire recording (null bias) and any linear trends were also removed. Stochastic properties of the time series of differences were described by the autocorrelation function. The temporal pattern of transient drifts was characterized by the coherent averaging of positive and negative transients, synchronized by their peak/trough values. RESULTS: On average, autocorrelation functions for differences between mean, systolic and diastolic values were significantly greater than zero for at least 24 beats, implying nonrandom differences. For mean BP, the peak value of positive and negative transient drifts were 4.98+/-3.61% and -6.75+/-7.48%, respectively. The average duration of these transients was approximately 20 s. Patients receiving (N=26) and not receiving beta-blockers (N=14) had similar autocorrelation functions indicative of nonrandom differences. The former showed lower peak/trough values in comparison with the latter, but differences were not statistically significant. CONCLUSION: The presence of transient drifts in beat-to-beat differences between finger and aortic BP can lead to erroneous results if biases are calculated using very short segments of data. Clinical and/or research applications using the Finapres, such as dynamic cerebral autoregulation modelling or sequence analysis for assessment of baroreceptor sensitivity can also be corrupted by the presence of nonrandom short-term fluctuations of the difference signal unless results are averaged for multiple segments of data.
Authors:
Ronney B Panerai; Emily L Sammons; Stephen M Smith; Wendy E Rathbone; Steve Bentley; John F Potter; Nilesh J Samani
Related Documents :
25161025 - Intra-abdominal hypertension in postoperative cardiac surgery patients.
25325125 - Treating essential hypertension. the first choice is usually a thiazide diuretic.
2258885 - Differences in blood pressure profile between young and elderly hypertensive patients.
25418495 - Cost estimation of hypertension management based on home blood pressure monitoring alon...
12808175 - Dialysis filter type determines the acute effect of haemodialysis on endothelial functi...
18608795 - Development of a novel nanocapsule formulation by emulsion-diffusion combined with high...
Publication Detail:
Type:  Clinical Trial; Comparative Study; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Blood pressure monitoring     Volume:  12     ISSN:  1359-5237     ISO Abbreviation:  Blood Press Monit     Publication Date:  2007 Dec 
Date Detail:
Created Date:  2007-11-16     Completed Date:  2008-03-11     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9606438     Medline TA:  Blood Press Monit     Country:  England    
Other Details:
Languages:  eng     Pagination:  369-76     Citation Subset:  IM    
Affiliation:
Department of Cardiovascular Sciences, University of Leicester, UK. rp9@le.ac.uk
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Angioplasty, Balloon
Aorta / physiology
Blood Pressure Determination* / instrumentation,  methods
Blood Pressure Monitors*
Electrocardiography
Female
Fingers
Heart Catheterization
Humans
Male
Middle Aged
Reproducibility of Results
Sensitivity and Specificity

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Validation of the SAA-102 home blood pressure monitor according to the protocols of the European Soc...
Next Document:  Predicted risk of coronary heart disease among persons with type 2 diabetes.