TOWARDS PROPOSITION OF A DIAGNOSTIC REFERENCE LEVEL FOR MAMMOGRAPHIC EXAMINATION IN THE GREATER KHORASAN PROVINCE, IRAN.
MedLine Citation:
PMID:  23209184     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Although, over the past few years, the application of mammography has risen up sharply in Iran, very little, if any, has been reported of the extent of patient's dose from this type of imaging. The purpose of this study was to establish local diagnostic reference level (DRL) arising from mammography in the great Khorasan province of Iran. It is generally assumed that the glandular tissue is the most vulnerable type of breast tissue. Therefore, the mean glandular dose (MGD) has been widely accepted as the most appropriate dosimetric quantity to predict the risk of radiation-induced cancer. Literary, DRL for mammography is defined as the 75th percentile of MGD distribution. In Khorasan province, 7 out of 40 centres were randomly selected. In this work, 100 patients were studied. Thermoluminescence dosimeters have been used to measure entrance surface doses (ESDs). Since, it is difficult to directly measure MGD, Monte Carlo model-based conversion factors were utilised to conclude MGD from ESD. The results have revealed that patients dose is varied widely. The measured ESDs ranged from 0.74 to 19.81 mGy for the craniocaudal (CC) view and 1.20 to 25.79 mGy for the mediolateral oblique (MLO) view. The average MGDs per image were 0.88 and 1.11 mGy for CC and MLO views, respectively. Based on the internationally adopted definition, DRL arising from mammography tests for Khorasan is 1.33 mGy. Implementation of a dose reduction programme is suggested because of the large variations observed in patient MGD values. In this study, the DRL value is significantly lower than the corresponding values suggested by other researchers elsewhere.
Authors:
M T Bahreyni Toossi; H Zare; Sh Bayani Roodi; M Hashemi; F Akbari; M Malekzadeh
Related Documents :
11248634 - Return of spontaneous erection during long-term intracavernosal alprostadil (caverject)...
23089004 - A regulatory perspective on whether the system of radiation protection is fit for purpose.
24777584 - Commissioning and first clinical application of marc treatment.
16583464 - Evaluation of the comparative efficacy and tolerability of rofecoxib and naproxen in ch...
1971604 - Intravenous omeprazole in patients with zollinger-ellison syndrome undergoing surgery.
8489474 - The impact of autologous bone marrow transplantation on hematopoietic recovery after hi...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-12-2
Journal Detail:
Title:  Radiation protection dosimetry     Volume:  -     ISSN:  1742-3406     ISO Abbreviation:  Radiat Prot Dosimetry     Publication Date:  2012 Dec 
Date Detail:
Created Date:  2012-12-4     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8109958     Medline TA:  Radiat Prot Dosimetry     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Pathophysiology and Clinical Manifestations of the ?-Thalassemias.
Next Document:  EARLY IN SITU MEASUREMENT OF RADIOACTIVE FALLOUT IN FUKUSHIMA CITY DUE TO FUKUSHIMA DAIICHI NUCLEAR ...