Document Detail


Time constant of thermistors and its role in thermodilution methods.
MedLine Citation:
PMID:  1106949     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Thermolution serves for measuring either the cardiac output or the size of cardiac ventricles. In the former instance, an accurate determination of the area under the dilution curve, and in the latter, a true tracing of the thermal changes with time are of special importance. Because the size of the area is independent of the time constant, and a curve devoid of marked stroke waves is better suited for automatic integration, thermistors with time constants of 0.8 to 1.0 sec are chosen for this purpose. A reliable determination of the time constant is described. In measurements of the size of cardiac ventricles, a true course of thermal changes with time can be recorded with a thermistor possessing a very short time constant: 0.01 to 0.02 seconds. It is very difficult to make such thermistorized probes or catheters. It is easier to make thermistors with a time constant of 0.1 o 0.2 sec, well insulated, which may serve both requirements. By compensation, the time constant is reducible to 0.01 to 0.2 sec, making possible a true-shape recording of thermal changes for the measurement of the ventricular size, or the constant can be prolonged to 0.8 to 1.0 sec for instrumental integration. If both the shape and the time course of the thermal changes have to be truly recorded, then a non-insulated thermistor with a very short time constant has to be used.
Authors:
F Zajic; Z Brun; M Novotny
Related Documents :
7640119 - Continuous measurement of cardiac output during aortic cross-clamping by the oesophagea...
17670579 - Levosimendan for patients with impaired left ventricular function undergoing cardiac su...
8823649 - Testing the safety of baxter continuous cardiac output monitoring system.
9924219 - Sevoflurane pharmacokinetics: effect of cardiac output.
11200129 - Indications, results, and pitfalls in the surgery of constrictive pericarditis.
7693079 - The value of doppler echocardiography in cardiac output detection.
22750409 - Zebrafish mef2ca and mef2cb are essential for both first and second heart field cardiom...
10147819 - Percutaneous transluminal coronary angioplasty through six french catheters.
7987879 - Total coronary artery occlusion late after successful coronary angioplasty of moderatel...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Cor et vasa     Volume:  17     ISSN:  0010-8650     ISO Abbreviation:  Cor Vasa     Publication Date:  1975  
Date Detail:
Created Date:  1976-03-24     Completed Date:  1976-03-24     Revised Date:  2008-11-21    
Medline Journal Info:
Nlm Unique ID:  0372614     Medline TA:  Cor Vasa     Country:  CZECHOSLOVAKIA    
Other Details:
Languages:  eng     Pagination:  204-11     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Blood Volume
Cardiac Output*
Heart Catheterization
Humans
Indicator Dilution Techniques*
Methods
Temperature
Thermometers*
Ventricular Function

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  "Mental illness" and "disease": outmoded concepts in alcohol and drug rehabilitation.