Document Detail


Thrombosis and Cable Damage in the HeartWare Pump: Clinical Decisions and Surgical Technique.
MedLine Citation:
PMID:  23263342     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Exchange of the HeartWare HVAD made necessary by thrombosis or cable damage is rare, but it is a complex procedure associated with morbidity. Less invasive exchange procedures may contribute to faster postoperative recovery and early mobilization. Between September 2009 and April 2012, 225 patients (median age 55.4 years, range 7-82 years, 40 of them women) were supported with the HeartWare HVAD at our institution. Cumulative follow-up in all 225 patients was 151.9 patient/years. In six patients, early pump thrombosis (<30 days) requiring pump exchange occurred after a median time of 7 (2-9) days. In six patients, late pump thrombosis requiring pump exchange occurred after a median of 380 (84-705) days. The overall incidence was 5.3% with 0.079 thromboses per year. In two instances of accidental cable damage as a result of massive external mechanical impact, pump exchange was necessary. We describe a safe and less invasive technique for the explantation and exchange of the HeartWare HVAD through a left thoracotomy. Pump thrombosis of the HeartWare HVAD is a very rare condition caused mostly by new onset of heparin-induced thrombocytopenia type II, mismanagement of anticoagulation, or hypercoagulability in the case of severe sepsis. Since the introduction of the sintered inflow cannula no early thrombosis has occurred. Pump exchange in the case of hemolysis should not be delayed. The cable of the HeartWare HVAD is very reliable and breaks only after excessive external impact. A minimally invasive approach for pump exchange on cardiopulmonary bypass for pump thrombosis and off-pump for cable damage or pump explantation is recommended.
Authors:
Evgenij V Potapov; Alexander Stepanenko; Friedrich Kaufmann; Ewald Henning; Juliana Vierecke; Elke Lehmkuhl; Roland Hetzer; Thomas Krabatsch
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-12-19
Journal Detail:
Title:  ASAIO journal (American Society for Artificial Internal Organs : 1992)     Volume:  -     ISSN:  1538-943X     ISO Abbreviation:  ASAIO J.     Publication Date:  2012 Dec 
Date Detail:
Created Date:  2012-12-24     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9204109     Medline TA:  ASAIO J     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
From the Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum Berlin, Berlin, Germany.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Predictive Value of the Model for End-Stage Liver Disease Score in Patients Undergoing Left Ventricu...
Next Document:  Optimal growth of Ge-rich dots on Si(001) substrates with hexagonal packed pit patterns.