Document Detail


Three-dimensional paper-based electrochemiluminescence immunodevice for multiplexed measurement of biomarkers and point-of-care testing.
MedLine Citation:
PMID:  22074665     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
In this work, electrochemiluminescence (ECL) immunoassay was introduced into the recently proposed microfluidic paper-based analytical device (μPADs) based on directly screen-printed electrodes on paper for the very first time. The screen-printed paper-electrodes will be more important for further development of this paper-based ECL device in simple, low-cost and disposable application than commercialized ones. To further perform high-performance, high-throughput, simple and inexpensive ECL immunoassay on μPAD for point-of-care testing, a wax-patterned three-dimensional (3D) paper-based ECL device was demonstrated for the very first time. In this 3D paper-based ECL device, eight carbon working electrodes including their conductive pads were screen-printed on a piece of square paper and shared the same Ag/AgCl reference and carbon counter electrodes on another piece of square paper after stacking. Using typical tris-(bipyridine)-ruthenium (Ⅱ) - tri-n-propylamine ECL system, the application test of this 3D paper-based ECL device was performed through the diagnosis of four tumor markers in real clinical serum samples. With the aid of a facile device-holder and a section-switch assembled on the analyzer, eight working electrodes were sequentially placed into the circuit to trigger the ECL reaction in the sweeping range from 0.5 to 1.1 V at room temperature. In addition, this 3D paper-based ECL device can be easily integrated and combined with the recently emerging paper electronics to further develop simple, sensitive, low-cost, disposable and portable μPAD for point-of-care testing, public health and environmental monitoring in remote regions, developing or developed countries.
Authors:
Lei Ge; Jixian Yan; Xianrang Song; Mei Yan; Shenguang Ge; Jinghua Yu
Related Documents :
24519475 - Feasibility of error-based electrotactile and auditive feedback in prosthetic walking.
24300295 - Design of skin penetration enhancers using replacement methods for the selection of the...
7836585 - Optimal replacement of mastitic cows determined by a hierarchic markov process.
19528625 - Genetic evaluation of susceptibility to clinical mastitis in spanish holstein cows.
23153355 - Concussive injury before or after controlled cortical impact exacerbates histopathology...
12098405 - Legal vulnerability of assessment tools.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-11-8
Journal Detail:
Title:  Biomaterials     Volume:  -     ISSN:  1878-5905     ISO Abbreviation:  -     Publication Date:  2011 Nov 
Date Detail:
Created Date:  2011-11-14     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8100316     Medline TA:  Biomaterials     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2011 Elsevier Ltd. All rights reserved.
Affiliation:
School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Polyethylene glycol-conjugated hyaluronic acid-ceramide self-assembled nanoparticles for targeted de...
Next Document:  Strong light-induced reorganization of pigment-protein complexes of thylakoid membranes in rye (spec...