Three-dimensional interface geometry of the human heart with the artificial heart.
MedLine Citation:
PMID:  1768498     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The interface geometry of human and artificial hearts was defined. It included: 1) the approximate mitral orifice and mitral orifice planes; 2) the approximate tricuspid orifice and tricuspid orifice planes; 3) the long and short diameters of the aorta; 4) the long and short diameters of the pulmonary artery; and 5) the angles between the mitral orifice and tricuspid orifice planes, as well as the axes of the aorta and pulmonary artery. The orifice plane was defined as a plane such that the sum of the squared distances between the plane and points on the orifice contour was minimized. A standard coordinate system was also defined, whose origin was the centroid of the approximate mitral orifice. Its X-Y plane was the approximate mitral orifice plane. One set of interface parameters was determined using magnetic resonance images of a volunteer's heart. The angle between the approximate mitral orifice plane and tricuspid plane was found to be 19.9 degrees. The areas of the approximate mitral and tricuspid orifices were 1020 and 1655 mm2, respectively. The approximate mitral orifice was covered by a 44 x 40 mm rectangle and the approximate tricuspid orifice was covered by a 59 x 41 mm rectangle. This interface geometry is important, not only in the manufacture of artificial hearts of precise dimensions, but also in avoiding complications due to their long-term use.
Authors:
C Uyama; T Akutsu
Related Documents :
2974298 - Transient neonatal tricuspid regurgitation: a doppler echocardiographic study of three ...
1126208 - Midsystolic clicks originiating from tricuspid valve structures: a sequela of heroin-in...
1921438 - Pulmonary atresia and intact ventricular septum. definitive repair in the neonatal period.
17383758 - Geometric and hemodynamic determinants of functional tricuspid regurgitation: a real-ti...
19592268 - Increased number of cerebral emboli during percutaneous endocardial pulmonary vein isol...
22194108 - Superior and anterior inferior cerebellar arteries and their relationship with cerebell...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  ASAIO transactions / American Society for Artificial Internal Organs     Volume:  37     ISSN:  0889-7190     ISO Abbreviation:  ASAIO Trans     Publication Date:    1991 Oct-Dec
Date Detail:
Created Date:  1992-02-27     Completed Date:  1992-02-27     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  8611947     Medline TA:  ASAIO Trans     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  608-14     Citation Subset:  IM    
Affiliation:
Department of Investigative Radiology, National Cardiovascular Center, Osaka, Japan.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Computer Graphics*
Computer Simulation*
Heart / anatomy & histology*
Heart, Artificial*
Humans
Magnetic Resonance Imaging
Models, Anatomic
Software