Three-dimensional accuracy of implant placement in a computer-assisted navigation system.
MedLine Citation:
PMID:  16796293     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
PURPOSE: To evaluate the 3-dimensional accuracy of dental implant drilling in a computer-assisted navigation (CAN) system using simulated mandible models. MATERIALS AND METHODS: Eight acrylic resin models were fabricated to simulate human mandibles containing mandibular canal (MC). Computerized tomography (CT) scans were obtained for each model, and the data were transferred to the system for dental implant planning. The models were mounted on a phantom head to simulate surgical situation. The assessment parameters included entry point localization, drill path angulation, and drilling depth, which were directly measured by sectioning of the models. RESULTS: Eighty drill holes were made on the 8 models. The entry point localization showed a mean deviation of 0.43 mm (range, 0 to 2.23 mm; SD, 0.56 mm) from the plan. The angulation showed a mean deviation of 4.0 degrees (range, 0 to 13.6 degrees; SD, 3.5 degrees). The drill aimed at stopping as close to the upper border of the MC as possible without perforating it, and 65% (52) of the drill holes managed to come within 1 mm. Another 5% of the holes stopped 1 to 2 mm above the MC. None of the drill holes stopped more than 2 mm above the MC. However, 30% (24 of 80) of the drill holes perforated the upper border of MC, and the mean depth of perforation was 0.37 mm (range, 0.01 to 1.04 mm; SD, 0.28 mm). DISCUSSION AND CONCLUSION: The CAN system identified the entry location and angulation with mean deviations of 0.43 mm and 4 degrees, respectively. About two thirds of the drillings achieved accuracy within 1 mm above the MC. Thirty percent perforated into the MC, and the maximal depth was 1.04 mm. In the planning stage, the maximal depth of the implant should be at least 1.1 mm above the superior border of MC as a safety margin.
Authors:
Wai-Kuen Chiu; Wai-Kuen Luk; Lim-Kwong Cheung
Related Documents :
24719853 - Morphological effects of ha on the cell compatibility of electrospun ha/plga composite ...
23375393 - A nano-hydroxyapatite - pullulan/dextran polysaccharide composite macroporous material ...
9874043 - Direct stent implantation without predilatation using the multilink stent.
Publication Detail:
Type:  Evaluation Studies; Journal Article    
Journal Detail:
Title:  The International journal of oral & maxillofacial implants     Volume:  21     ISSN:  0882-2786     ISO Abbreviation:  Int J Oral Maxillofac Implants     Publication Date:    2006 May-Jun
Date Detail:
Created Date:  2006-06-26     Completed Date:  2006-08-07     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8611905     Medline TA:  Int J Oral Maxillofac Implants     Country:  United States    
Other Details:
Languages:  eng     Pagination:  465-70     Citation Subset:  D; IM    
Affiliation:
Discipline of Oral and Maxillofacial Surgery, Faculty of Dentistry, The University of Hong Kong. chiuwk1@hkusua.hku.hk
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Dental Implantation, Endosseous / methods*
Dental Models
Mandible / radiography
Surgery, Computer-Assisted / methods*
Tomography, X-Ray Computed / methods

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Oral rehabilitation of a patient with diffuse lymphangiomatosis affecting the maxilla: a case report...
Next Document:  Repeated distraction osteogenesis for excessive vertical alveolar augmentation: a case report.