Document Detail


Ten-year results after cementless THA with a sandwich-type alumina ceramic bearing.
MedLine Citation:
PMID:  21053885     Owner:  NLM     Status:  In-Process    
Abstract/OtherAbstract:
We analyzed the long-term results of a single-surgeon series of 102 cementless total hip arthroplasties (THAs) performed using a sandwich-type alumina ceramic bearing. The prostheses involved a porous-coated acetabular socket, a polyethylene-alumina composite liner, a 28-mm alumina head, and a grit-blasted titanium-alloy stem. Mean patient age at the time of THA was 39 years (range, 18-66 years), and 76% of the patients were younger than 50 years. All procedures were performed with use of the same surgical technique and the same implant at a single center. Mean follow-up was 115 months (range, 84-133 months). When failure was defined as revision of either the acetabular or the femoral component for any reason, Kaplan-Meier survival probability at 10 years was 95.3% (95% confidence interval, 89.5%-100%). Mean Harris Hip Score improved from 47 points (range, 16-70 points) preoperatively to 95 points (range, 85-100 points) at final follow-up. No radiographically detectable osteolysis around the acetabular or femoral component was observed in any hip. No patient reported squeaking in the operated hip. During the follow-up period, 3 hips (3%) required revision surgery; 2 underwent acetabular revision because of a ceramic liner fracture and 1 underwent revision for early loosening of the acetabular cup. Ten-year results of cementless THA with a sandwich-type alumina ceramic bearing were encouraging, and no great increase in ceramic failure rate was observed, which contrasts with the findings of previously reported short-term follow-up studies.
Authors:
Youn-Soo Park; Se-Jun Park; Seung-Jae Lim
Related Documents :
19865795 - A prospective study of hip revision surgery using the exeter long-stem prosthesis: func...
17672155 - 9- to 11-year results of cemented titanium mueller straight stem in total hip arthropla...
20824405 - Quality of life following proximal femoral replacement using a modular system in revisi...
20041375 - Clinical outcome study and radiological findings of zweymuller metal on metal total hip...
17261145 - Trauma patients in the intensive care unit: short- and long-term survival and predictor...
23322265 - Sports involvement following acl reconstruction is related to lower extremity neuromusc...
Publication Detail:
Type:  Journal Article     Date:  2010-11-02
Journal Detail:
Title:  Orthopedics     Volume:  33     ISSN:  1938-2367     ISO Abbreviation:  Orthopedics     Publication Date:  2010 Nov 
Date Detail:
Created Date:  2010-11-08     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7806107     Medline TA:  Orthopedics     Country:  United States    
Other Details:
Languages:  eng     Pagination:  796     Citation Subset:  IM    
Copyright Information:
Copyright 2010, SLACK Incorporated.
Affiliation:
Department of Orthopedic Surgery, Sungkyunkwan University School of Medicine, Samsung Medical Center, Seoul, South Korea.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Timing of DVT prophylaxis and risk of postoperative knee prosthesis infection.
Next Document:  One-stage posterior approach and combined interbody and posterior fusion for thoracolumbar spinal tu...