Temporary Epicardial Pacemaker Wires: Significance of Position and Electrode Type.
MedLine Citation:
PMID:  23034875     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Objective To determine the pacing and sensing properties of different temporary epicardial pacemaker electrodes after cardiac surgery depending on position at the heart and time after surgery.Methods From September 2009 to October 2010, 60 patients undergoing cardiac surgery were prospectively randomized into two groups: group O: Osypka-electrodes (n = 30), group M: Medtronic-electrodes (n = 30). In position 1, the bipolar electrodes were inserted onto the anterior wall of the right ventricle and at the right atrial auricle, in position 2, onto the diaphragmal wall of the right ventricle and at the aortic aspect of the superior vena cava medial close to the atrium. Sensing values and pacing thresholds were measured for all electrodes during surgery, on day 1 and every second day up to day 10 after surgery.Results In both groups, pacing thresholds (both positions) were higher during surgery (ventricle 3.1 ± 0.6 V, atrium 3.1 ± 0.3 V) than at day 1 (ventricle 2.4 ± 0.7 V, atrium 2.4 ± 0.3 V) and increased during the perioperative course until day 10 (ventricle 4.7 ± 1.0 V, atrium 4.9 ± 1.1 V, p = 0.04, p = 0.02). P and R wave amplitudes did not change over time (atrium 5.1 ± 0.1 mV initially, 4.2 ± 0.1 mV at removal (p = ns); ventricle 10.4 ± 0.2 mV vs. 10.1 ± 0.25 mV). Group M had better median pacing thresholds compared with group O (atrium: 2.9 ± 0.6 V vs. 3.9 ± 0.7 V, p = 0.04 and ventricle: 2.6 ± 0.6 V vs. 3.9 ± 0.6 V, p = 0.045). Atrial position 1 was superior to position 2 concerning pacing thresholds of Medtronic electrodes (2.1 ± 0.3 mV vs. 3.4 ± 0.4 mV, p = 0.02). Osypka-electrodes were easier to handle due to their more pliable texture.Conclusions 1. Up to postoperative day 10, adequate pacing and sensing performance was achieved by both electrode types in each position. 2. Medtronic electrodes had better pacing thresholds in atrium and ventricle after day 5. 3. Positioning of pacemaker electrodes does not alter functionality. 4. Handling of Osypka electrodes was easier than that of Medtronic electrodes.
Authors:
Raed Aser; Coskun Orhan; Bernd Niemann; Peter Roth; Andre Perepelitsa; Tim Attmann; Andreas Böning
Related Documents :
12775205 - The effect of physiotherapy treatment on oxygen consumption and haemodynamics in patien...
24433855 - Clinical practice, resource utilization, and outcomes of device closure of patent foram...
1468485 - Hyperbaric oxygen therapy for control of intractable cyclophosphamide-induced hemorrhag...
2775635 - Intravenous pentoxifylline in the treatment of rest pain: a preliminary report.
17109095 - Study of nasopharyngeal bacterial flora. second report. variations in nasopharyngeal ba...
6611325 - Functional evaluation of distal esophagus and lower esophageal sphincter after esophago...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-10-3
Journal Detail:
Title:  The Thoracic and cardiovascular surgeon     Volume:  -     ISSN:  1439-1902     ISO Abbreviation:  Thorac Cardiovasc Surg     Publication Date:  2012 Oct 
Date Detail:
Created Date:  2012-10-4     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7903387     Medline TA:  Thorac Cardiovasc Surg     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Affiliation:
Department of Cardiovascular Surgery, University Hospital Giessen, Giessen, Germany.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Coronary Artery Fistula between Left Coronary Artery and Coronary Sinus in Newborn.
Next Document:  A Strange Bullet which Caused Chylomediastinum and Chyloptysis.