Document Detail

Temporal contrast sensitivity in human infants.
MedLine Citation:
PMID:  1509708     Owner:  NLM     Status:  MEDLINE    
Temporal contrast sensitivity was measured in 1.5- and 3-month-old infants using the FPL procedure. Stimuli were 0.1 c/deg counterphase-flickering sinewave gratings. Temporal rates ranged from 1 to 20 Hz. Because the spatial sinewave underwent phase shifts of 180 degrees, the target could not be seen unless the observer was able to resolve it temporally. Adults were tested with the same temporal stimuli using a 2-alternative forced-choice procedure and a spatial frequency of 0.5 c/deg. Adult temporal CSFs were bandpass with peak sensitivity at 10 Hz. Infant temporal CSFs were lowpass at 1.5 months and bandpass at 3 months. The infants' contrast sensitivity was over a log-unit lower than adults'. Unlike spatial CSFs, infant sensitivity was closest to adult sensitivity at the highest flicker rate.
E E Hartmann; M S Banks
Related Documents :
7471928 - Intersensory function in newborns: effect of sound on visual preferences.
5683058 - Monocular compared to binocular depth perception in human infants.
10321788 - Maturation of the flash visual evoked potential in preterm infants.
2809778 - Auditory brainstem-evoked potentials in term infants born to mothers addicted to opiates.
18395658 - The congenital diaphragmatic hernia study group: a voluntary international registry.
17277578 - Motor evoked potentials after transcranial magnetic stimulation support hypothesis of c...
Publication Detail:
Type:  Journal Article; Research Support, U.S. Gov't, P.H.S.    
Journal Detail:
Title:  Vision research     Volume:  32     ISSN:  0042-6989     ISO Abbreviation:  Vision Res.     Publication Date:  1992 Jun 
Date Detail:
Created Date:  1992-09-24     Completed Date:  1992-09-24     Revised Date:  2007-11-14    
Medline Journal Info:
Nlm Unique ID:  0417402     Medline TA:  Vision Res     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  1163-8     Citation Subset:  IM    
Department of Ophthalmology, Children's Hospital and Medical Center, Seattle, WA 98105.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Aging / physiology
Contrast Sensitivity / physiology*
Sensory Thresholds / physiology
Time Factors
Visual Perception / physiology
Grant Support

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Previous Document:  Infant temporal contrast sensitivity at low temporal frequencies.
Next Document:  Control of interocular suppression as a function of differential image blur.