Document Detail


Teflon felt wrapping repair for coronary perforation after failed angioplasty.
MedLine Citation:
PMID:  17126169     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Acute type III perforation caused by failed angioplasty is a lethal complication that often requires emergency operation. However, the presence of multiple rigid stents beneath the subepicardial hematoma disturbs optimal revascularization and hemostasis. Teflon felt (Meadox Medical Inc, Oakland, NJ) wrapping repair is a simple salvage technique that allows stable hemostasis and the rescue of the entire blood flow of the coronary artery. This procedure was successfully performed with type III perforation of the left anterior descending coronary artery on 2 patients subjected to multiple stenting.
Authors:
Yoshito Inoue; Toshihiko Ueda; Shinichi Taguchi; Ichiro Kashima; Kiyoshi Koizumi; Shigetaka Noma
Related Documents :
9234139 - Angioscopic evaluation of an endoluminal aortic graft: the first clinical experience.
16816449 - Very late bare-metal stent thrombosis. a case report and review of the literature.
1933639 - Balloon expandable stents for acute closure post failed coronary angioplasty: case repo...
15982759 - New diagnostic technique in multi-slice computed tomography for in-stent restenosis: pi...
16197829 - Stent-assisted arterial reconstruction of traumatic extracranial carotid dissections.
19455089 - Outcome of carotid artery stenting at 2 years follow-up: comparison of nitinol open cel...
21607229 - Stroke due to thromboembolism from congenital aneurysm of ventricular septum.
10798419 - Congenital heart surgery nomenclature and database project: tetralogy of fallot.
21548999 - Frozen elephant trunk: a technique which can be offered in complex pathology to fix the...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  The Annals of thoracic surgery     Volume:  82     ISSN:  1552-6259     ISO Abbreviation:  Ann. Thorac. Surg.     Publication Date:  2006 Dec 
Date Detail:
Created Date:  2006-11-27     Completed Date:  2006-12-12     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  15030100R     Medline TA:  Ann Thorac Surg     Country:  Netherlands    
Other Details:
Languages:  eng     Pagination:  2312-4     Citation Subset:  AIM; IM    
Affiliation:
Department of Cardiovascular Surgery, Saiseikai Utsunomiya Hospital, Tochigi, Japan. yosito_inoue@saimiya.com
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged, 80 and over
Angioplasty, Transluminal, Percutaneous Coronary / adverse effects*
Biocompatible Materials*
Coronary Angiography
Coronary Artery Bypass
Coronary Stenosis / surgery
Coronary Vessels / injuries*
Hemostasis, Surgical / methods
Humans
Male
Middle Aged
Polytetrafluoroethylene*
Stents / adverse effects*
Chemical
Reg. No./Substance:
0/Biocompatible Materials; 9002-84-0/Polytetrafluoroethylene

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Bridging the cleft over the throbbing heart.
Next Document:  Thrombin during cardiopulmonary bypass.