Document Detail


Technique for using video microscopy and indicator dilution for repeated measurements of cardiac output in small animals.
MedLine Citation:
PMID:  11374611     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: The authors developed an indicator dilution technique for small animals to repeatedly determine cardiac output and blood volume without cardiac instrumentation or blood sampling. METHODS: Observations were made in the hamster (N = 32, 70 mg/kg pentobarbital) cremaster using in vivo fluorescence videomicroscopy. Fluorescein isothiocyanate-conjugated bovine serum albumin (10 mg/ml) was injected as a bolus dose (right jugular) while video recording the light intensity in a 20-microm arteriole (intensified charge-coupled device [CCD] camera at fixed gain). The intensity signal was analyzed over time (background subtracted) and calibrated to the dye concentration. The ex vivo calibration was performed using a constant optical path length (20 microm) and a range of dye and hematocrit concentrations. In vivo tube hematocrit was determined using standard methods with fluorescently labeled erythrocytes. Thus, quenching of the fluorescence signal by hemoglobin was corrected for the calibration, and the plasma space in the arteriole was determined. The steady state dye concentration measured by the light intensity at 2 min was not different from the dye concentration found by direct spectrophotometric analysis of the plasma. RESULTS: Cardiac index was calculated as milliliters of blood per minute per kilogram body weight. The calculated cardiac index was 359 +/- 18 ml.min(-1).kg(-1), which is not different from the reported values for hamsters. Cardiac output was increased twofold when enough intravenous nitroprusside or nitroglycerine was injected to decrease mean arterial pressure from 90 to 70 mmHg. Cardiac output was elevated during dobutamine infusion (16 microg.kg(-1).min(-1)) and decreased during esmolol infusion (50, 75.kg(-1).min(-1)). Blood volume determined from the steady state dye concentrations was 6.2 +/- 0.5 ml/100 g body weight, within the normal range for hamsters. CONCLUSIONS: Fluorescent dye dilution and video microscopy can be used to repeatedly determine cardiac output or blood volume in small animals.
Authors:
R J Rivers; J B Beckman; M D Frame
Publication Detail:
Type:  Journal Article; Research Support, U.S. Gov't, P.H.S.    
Journal Detail:
Title:  Anesthesiology     Volume:  94     ISSN:  0003-3022     ISO Abbreviation:  Anesthesiology     Publication Date:  2001 Mar 
Date Detail:
Created Date:  2001-05-25     Completed Date:  2001-06-14     Revised Date:  2007-11-14    
Medline Journal Info:
Nlm Unique ID:  1300217     Medline TA:  Anesthesiology     Country:  United States    
Other Details:
Languages:  eng     Pagination:  489-95     Citation Subset:  AIM; IM    
Affiliation:
Department of Anesthesiology, University of Rochester School of Medicine and Dentistry, New York 14642, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Animals
Blood Volume
Cardiac Output*
Cricetinae
Fluorescein-5-isothiocyanate
Fluorescent Dyes
Indicator Dilution Techniques*
Male
Mesocricetus
Microscopy, Video*
Grant Support
ID/Acronym/Agency:
55492//PHS HHS
Chemical
Reg. No./Substance:
0/Fluorescent Dyes; 3326-32-7/Fluorescein-5-isothiocyanate

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Blockade of AMPA receptors and volatile anesthetics: reduced anesthetic requirements in GluR2 null m...