Document Detail


Technical aspects of harvesting the radial artery with the harmonic scalpel.
MedLine Citation:
PMID:  14721806     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: Harvesting the radial artery (RA) with ultrasonic dissection with the Harmonic Scalpel reduces spasm induced by surgical handling. Topical exposure to phentolamine methanesulphonate (Regitine) exerts an additional effect of vasodilatation. METHODS: Between January and December 2002, the RA was harvested as a pediculated vessel with the Harmonic Scalpel in 145 consecutive patients undergoing myocardial revascularization. A fasciotomy of the pedicle was performed after harvest ing. A composite graft with the reverse free RA on the in situ left internal thoracic artery (ITA) was prepared before the construction of distal coronary anastomoses. The RA was then placed in a syringe filled with Regitine (0.07 microg/mL) for 10 minutes. \par RESULTS: The mean number of grafts/patient was 3.0. The mean number of RA anastomoses was 2.0/patient. Left ITA free flow was 105 +/- 34 mL/min. Regitine increased the RA free flow from 60 +/- 35 mL/min to 82 +/- 30 mL/min (P <.05). Fourteen patients underwent postoperative coronary angiography. All RA anastomoses were patent. CONCLUSION: The compound effect of RA harvesting with the Harmonic Scalpel and topical treatment with the alpha- blocking agent Regitine increases the RA free flow and significantly decreases intraoperative spasticity.
Authors:
C Locker; Y Ben-Gal; Y Paz; O Lev-Ran; N Nesher; G Uretzky; R Mohr; I Shapira
Related Documents :
16502656 - Turbulent flow evaluation of the venous needle during hemodialysis.
2429596 - An endoscopic method of tympanic membrane fluorescein angiography.
1083296 - Preoperative coronary angiographic prediction of bypass flow and short-term patency.
2439776 - A quantitative and qualitative comparison of fibrin glue, albumin, and blood as agents ...
22180216 - Real-time phase-contrast mri of cardiovascular blood flow using undersampled radial fas...
11339186 - Intraobserver and interobserver variability of transabdominal doppler velocimetry measu...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  The heart surgery forum     Volume:  6     ISSN:  1522-6662     ISO Abbreviation:  Heart Surg Forum     Publication Date:  2003  
Date Detail:
Created Date:  2004-01-14     Completed Date:  2004-05-04     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  100891112     Medline TA:  Heart Surg Forum     Country:  United States    
Other Details:
Languages:  eng     Pagination:  345-7     Citation Subset:  IM    
Affiliation:
Department of Cardiothoracic Surgery, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Aged, 80 and over
Female
Humans
Male
Middle Aged
Myocardial Revascularization / methods*,  mortality
Radial Artery*
Surgical Instruments*
Survival Rate
Tissue and Organ Harvesting / methods*
Ultrasonics

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Beating heart revascularization using only bilateral internal thoracic arteries for triple-vessel di...
Next Document:  Midterm results of routine bilateral internal thoracic artery grafting.