Document Detail


A technical strategy for carotid artery stenting: suboptimal prestent balloon angioplasty without poststenting balloon dilatation.
MedLine Citation:
PMID:  20871446     Owner:  NLM     Status:  In-Process    
Abstract/OtherAbstract:
BACKGROUND: Traditional carotid artery stenting (CAS) consists of predilatation, optional deployment of embolic protection devices, stenting, and poststent angioplasty. Each step carries a risk of thromboembolism.
OBJECTIVE: To design a new and simplified procedural protocol, suboptimal balloon angioplasty without routine poststenting balloon dilatation, and to describe the efficacy this protocol in terms of procedural risks and angiographic and clinical outcomes.
METHODS: Over a period of 6 years, 161 carotid artery stenoses in 156 consecutive patients were treated by CAS with embolic protection devices. Among them, 110 lesions in 107 patients (68.3%) were treated by our simplified method (symptomatic, > 50% stenosis; asymptomatic, > 70% stenosis). Overall, 98 lesions (88.3%) had severe stenosis (> 70%).
RESULTS: The mean stenosis was reduced from 77% to 10% after CAS. A persistent neurological deficit developed in 2 patients from thromboembolism. Hemodynamic insufficiency developed in 14 lesions during CAS (12.7%). The ipsilateral stroke and mortality rate was 4.5% within 1 month after CAS (asymptomatic, 3.6%; symptomatic, 4.8%). Over a mean of 19 months of follow-up, additive angioplasty was performed in 2 patients as a result of progressive restenosis (≥ 50%). A comparison of the balloon sizes of the prestent angioplasty for group 1 (balloon, ≤ 4 mm) and group 2 (balloon, ≥ 5 mm) showed no difference in restenosis between the groups at 15 months of follow-up after CAS.
CONCLUSION: Our CAS technique with suboptimal prestenting angioplasty without routine use of poststenting dilatation is safe, simple, and efficient with acceptable risks.
Authors:
Sung-Chul Jin; O-Ki Kwon; Chang Wan Oh; Cheolkyu Jung; Moon Gu Han; Hee-Joon Bae; Sang Hyung Lee; Young Sub Jung; Moon Hee Han; Hyun-Seung Kang
Related Documents :
19494416 - Intra-aortic balloon pump related thrombus in the proximal descending thoracic aorta wi...
2967106 - A newly designed angioplasty catheter: "the gemini balloon".
1941126 - Enlargement of basilar artery aneurysms following balloon occlusion--"water-hammer effe...
4037916 - Complications of ascending aortic intraaortic balloon pump cannulation.
6708456 - Morphologic investigation of coronary arteries subjected to hypertension by experimenta...
11896076 - Chlamydia pneumoniae in infrequently examined blood vessels.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Neurosurgery     Volume:  67     ISSN:  1524-4040     ISO Abbreviation:  Neurosurgery     Publication Date:  2010 Nov 
Date Detail:
Created Date:  2010-10-15     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7802914     Medline TA:  Neurosurgery     Country:  United States    
Other Details:
Languages:  eng     Pagination:  1438-42; discussion 1442-3     Citation Subset:  IM    
Affiliation:
Department of Neurosurgery, Seoul National University, Bundang Hospital, Seongnam, South Korea.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine