Document Detail


Synchronized mechanical ventilation using electrical activity of the diaphragm in neonates.
MedLine Citation:
PMID:  22954267     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
The electrical activity of the diaphragm (Edi) is measured by a specialized nasogastric/orogastric tube positioned in the esophagus at the level of the crural diaphragm. Neurally adjusted ventilatory assist (NAVA) uses the Edi signal as a neural trigger and intrabreath controller to synchronize mechanical ventilatory breaths with the patient's respiratory drive and to proportionally support the patient's respiratory efforts on a breath-by-breath basis. NAVA improves patient-ventilator interaction and synchrony even in the presence of large air leaks, and might therefore be an optimal option for noninvasive ventilation in neonates.
Authors:
Howard Stein; Kimberly Firestone; Peter C Rimensberger
Related Documents :
12794427 - Prone position in subarachnoid hemorrhage patients with acute respiratory distress synd...
16799347 - Effects of pneumoperitoneum and lps-induced endotoxemia on cerebral perfusion pressure ...
17946147 - Calculation of the mean pressure with less delay for real-time clinical monitoring.
8574657 - Activation of protein kinase c does not participate in disruption of the blood-brain ba...
16839847 - Differential changes in respiratory capacity and ischemia tolerance of isolated mitocho...
16493537 - Transintestinal systemic oxygenation using perfluorocarbon.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Clinics in perinatology     Volume:  39     ISSN:  1557-9840     ISO Abbreviation:  Clin Perinatol     Publication Date:  2012 Sep 
Date Detail:
Created Date:  2012-09-07     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7501306     Medline TA:  Clin Perinatol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  525-42     Citation Subset:  IM    
Copyright Information:
Copyright © 2012 Elsevier Inc. All rights reserved.
Affiliation:
Department of Neonatology, Toledo Children's Hospital, 2142 North Cove Boulevard, Toledo, OH 43606, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Volume-limited and volume-targeted ventilation.
Next Document:  Weaning infants from mechanical ventilation.