Symptomatic carotid vasospasm caused by a distal-protection device during stent angioplasty of the right internal carotid artery.
MedLine Citation:
PMID:  20401301     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Percutaneous carotid stenting with a distal-protection device is now considered an alternative to standard carotid endarterectomy. Although distal-protection filter devices have been reported to reduce the risk of embolism and stroke, their use is associated with such iatrogenic complications as vasospasm, dissection, and guidewire entrapment. Herein, we report a case of symptomatic carotid vasospasm caused by a distal-protection filter device during right internal carotid artery intervention in a woman who had underlying coronary artery disease. We also discuss the management of iatrogenic carotid spasm.
Authors:
Rajesh Vijayvergiya; Parminder S Otaal; Shiv Bagga; Manish Modi
Publication Detail:
Type:  Case Reports; Journal Article    
Journal Detail:
Title:  Texas Heart Institute journal / from the Texas Heart Institute of St. Luke's Episcopal Hospital, Texas Children's Hospital     Volume:  37     ISSN:  1526-6702     ISO Abbreviation:  Tex Heart Inst J     Publication Date:  2010  
Date Detail:
Created Date:  2010-04-19     Completed Date:  2010-07-26     Revised Date:  2013-05-29    
Medline Journal Info:
Nlm Unique ID:  8214622     Medline TA:  Tex Heart Inst J     Country:  United States    
Other Details:
Languages:  eng     Pagination:  226-9     Citation Subset:  IM    
Affiliation:
Department of Cardiology, Postgraduate Institute of Medical Education & Research, 160012 Chandigarh, India. rajeshvijay999@hotmail.com
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Angioplasty, Balloon / adverse effects,  instrumentation*
Cardiac Pacing, Artificial
Carotid Artery, Internal* / radiography
Carotid Stenosis / complications,  radiography,  therapy*
Coronary Artery Disease / complications
Device Removal
Female
Filtration / instrumentation*
Humans
Iatrogenic Disease*
Middle Aged
Spasm / etiology*,  radiography,  therapy
Stents*
Stroke / etiology,  prevention & control
Treatment Outcome
Vasodilator Agents / therapeutic use