Document Detail


Sudden-onset paraplegia due to thrombosis of false aneurysm: late complication after prosthetic replacement of the descending thoracic aorta.
MedLine Citation:
PMID:  12016539     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Traumatic rupture involving the isthmus of the descending thoracic aorta is a rarely treated injury in vehicular accident victims. A possible long-term complication of prosthetic replacement of the damaged aortic segment is false aneurysm. This report describes a case of sudden-onset acute paraplegia resulting from thrombosis of a false aneurysm associated with a prosthesis placed 10 years earlier for repair of traumatic rupture of the aortic isthmus.
Authors:
E S Chemla; M A Combes; N D'Attelis; B Mongredien; P L Julia; J N Fabiani
Related Documents :
18765219 - Endovascular stenting of thoracic aortic aneurysm.
7841649 - Spinal cord protection in the absence of collateral circulation: meta-analysis of morta...
7064009 - Empyema and the urban black.
2146929 - Morphological and histopathological aspects of aneurysms after patch aortoplasty for co...
16127309 - Ect treatment of a patient with aortic aneurysms.
8911419 - Tuberculous pseudoaneurysm of the descending thoracic aorta: a case report and literatu...
154859 - Septal aneurysm and right ventricular obstruction: a case report.
9509659 - Transluminal coronary angioplasty and stenting in a patient with single coronary artery...
19876419 - Pseudoaneurysm in the left ventricular outflow tract after prosthetic aortic valve impl...
Publication Detail:
Type:  Case Reports; Journal Article     Date:  2002-05-21
Journal Detail:
Title:  Annals of vascular surgery     Volume:  16     ISSN:  0890-5096     ISO Abbreviation:  Ann Vasc Surg     Publication Date:  2002 May 
Date Detail:
Created Date:  2002-08-01     Completed Date:  2002-09-26     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  8703941     Medline TA:  Ann Vasc Surg     Country:  United States    
Other Details:
Languages:  eng     Pagination:  384-6     Citation Subset:  IM    
Affiliation:
Departement de Chirurgie Cardiovasculaire et de Transplantation, Hôpital Européen George Pompidou, Paris, France.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aneurysm, False / complications,  etiology*
Aneurysm, Ruptured / surgery*
Aortic Aneurysm, Thoracic / surgery*
Blood Vessel Prosthesis Implantation / adverse effects*
Fatal Outcome
Graft Occlusion, Vascular / complications,  radiography
Humans
Male
Paraplegia / etiology*
Time Factors

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Clinical and genetic features of vascular Ehlers-Danlos syndrome.
Next Document:  Occlusion of the aorta and inferior vena cava in a patient with circulating anticoagulants.