Studies of the dynamic response of esophageal manometry systems.
MedLine Citation:
PMID:  3715396     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Manometry with fluid-filled catheter systems remains an important technique to study esophageal physiology. The influence of mode of infusion, infusion flow rate, and catheter dimensions on the dynamic response and compliance of such systems was studied. To test the dynamic response, a method based on the step response was developed and applied. A pressure impulse--a step function--was produced by burning off a balloon connected to the system. The response to this well-defined impulse recorded by the system--the step response--was analyzed. The highest frequency to which the system responded satisfactorily--the limiting frequency--was calculated and used as a measure of performance. Compliance and inherent postocclusion pressure rise rate were also determined. In low-compliance systems noninfused or infused by hydraulic capillary infusion, limiting frequencies from 8 to 20 Hz were found, and this was much higher than in a high-compliance system infused by a syringe infusion pump. Smaller diameter and increased length of the manometry catheter decreased the limiting frequency. Increased infusion flow rate did not increase the limiting frequency. The step response test seems to be a simple test of dynamic response that can contribute to better understanding of problems involved in pressure recording with fluid-filled catheter systems. Well-performing fluid-filled manometry systems are adequate for esophageal manometry. Inherent postocclusion pressure rise rate is not a measure of dynamic response, and compliance is not the only determinant of performance.
Authors:
G B Pettersson; C O Kronogård; T Rådmark
Related Documents :
14604246 - Hemodynamic troubleshooting for mechanical malfunction of the extracorporeal membrane o...
8817966 - Controller for an axial flow blood pump.
15823696 - Cardiac torsion and electromagnetic fields: the cardiac bioinformation hypothesis.
21116846 - Determination of the critical buckling pressure of blood vessels using the energy appro...
6478556 - Phenol topically applied to canine left ventricular epicardium interrupts sympathetic b...
23402946 - Impact of continuous-flow left ventricular assist device support on right ventricular f...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Scandinavian journal of gastroenterology     Volume:  21     ISSN:  0036-5521     ISO Abbreviation:  Scand. J. Gastroenterol.     Publication Date:  1986 Apr 
Date Detail:
Created Date:  1986-07-02     Completed Date:  1986-07-02     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  0060105     Medline TA:  Scand J Gastroenterol     Country:  NORWAY    
Other Details:
Languages:  eng     Pagination:  305-12     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Catheterization / instrumentation
Esophagus / physiology*
Humans
Manometry / methods*
Pressure

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Radiolabelled colloid uptake distribution and pulmonary contents and localization of lysosomal enzym...
Next Document:  Evidence of involvement of the enteric nervous system in the effects of sodium deoxycholate on small...