Document Detail


Stimulus parameters in detection and reaction time.
MedLine Citation:
PMID:  2075415     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
This paper describes the relationship between detection threshold and reaction time for pure tones presented within the context of a two-interval forced-choice signal detection paradigm. Three variables manipulated were stimulus frequency (500 and 4,000 Hz), duration (50 and 300 ms) and rise/decay time for the longer stimulus (10 and 100 ms). The data for three practised, normal-hearing subjects indicated that stimulus energy was a good predictor of the detection threshold. Threshold measurements decreased as a function of the increase in stimulus duration and the decrease in rise/decay time. Both correct and incorrect reaction times also decreased with the increase in duration but were insensitive to a change in rise/decay time. The non-monotonicity of the function relating threshold and reaction time, as well as wide differences in reaction time for the same level of hearing acuity across subjects, led to the major conclusion that the two psychophysical measures were not interchangeable.
Authors:
S M Abel; D K Rajan; C Giguere
Related Documents :
17549875 - Inner and outer horizons of time experience.
24735465 - Single molecule studies of force-induced s2 site exposure in the mammalian notch negati...
8475775 - Evaluating the special role of time in the control of handwriting.
24886835 - Light-mediated control of gene expression in filamentous fungus trichoderma reesei.
20053085 - The roles of mask luminance and perceptual grouping in visual backward masking.
24343345 - Light extraction enhancement with radiation pattern shaping of leds by waveguiding nano...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Scandinavian audiology     Volume:  19     ISSN:  0105-0397     ISO Abbreviation:  Scand Audiol     Publication Date:  1990  
Date Detail:
Created Date:  1991-04-18     Completed Date:  1991-04-18     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0342230     Medline TA:  Scand Audiol     Country:  SWEDEN    
Other Details:
Languages:  eng     Pagination:  229-35     Citation Subset:  IM    
Affiliation:
Hearing Research Laboratory, Samuel Lunenfeld Research Institute, Mount Sinai Hospital, Toronto, Ontario, Canada.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Audiometry, Pure-Tone*
Auditory Threshold*
Humans
Reaction Time*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Recognition of low-pass filtered words in a noisy and reverberant environment with and without earmu...
Next Document:  Subjective ratings of noise-reduction hearing aids.