Stent graft exclusion of pseudo-aneurysm arising from PTFE hemodialysis graft after recurrence following ultrasound guided thrombin injection.
MedLine Citation:
PMID:  19085901     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
There are various non-invasive or minimally invasive techniques for management of pseudoaneurysms including ultrasound guided compression, ultrasound guided thrombin injection and covered stent placement. We report a case where a covered stent graft was successfully used for the treatment of a pseudoaneurysm directly arising from a PTFE graft which recurred 3 months following treatment with ultrasound guided thrombin injection.
Authors:
G Ananthakrishnan; R Bhat; A Severn; S Chakraverty
Publication Detail:
Type:  Case Reports; Journal Article    
Journal Detail:
Title:  The journal of vascular access     Volume:  9     ISSN:  1129-7298     ISO Abbreviation:  J Vasc Access     Publication Date:    2008 Oct-Dec
Date Detail:
Created Date:  2008-12-16     Completed Date:  2009-02-19     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  100940729     Medline TA:  J Vasc Access     Country:  Italy    
Other Details:
Languages:  eng     Pagination:  293-5     Citation Subset:  IM    
Affiliation:
Department of Radiology, Ninewells Hospital and Medical School, Dundee, Scotland. ganapathy.ananthakrishnan@nhs.net
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aneurysm, False / etiology,  pathology,  therapy*
Arteriovenous Shunt, Surgical / adverse effects*
Balloon Occlusion
Blood Vessel Prosthesis*
Blood Vessel Prosthesis Implantation / adverse effects*,  instrumentation
Coagulants / administration & dosage*
Female
Femoral Artery / surgery
Femoral Vein / surgery
Humans
Injections, Intralesional
Middle Aged
Polytetrafluoroethylene
Prosthesis Design
Recurrence
Renal Dialysis
Reoperation
Stents*
Thrombin / administration & dosage*
Treatment Failure
Ultrasonography, Interventional*
Chemical
Reg. No./Substance:
0/Coagulants; 9002-84-0/Polytetrafluoroethylene; EC 3.4.21.5/Thrombin

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Proximal radial artery ligation after distalization of a high flow brachio-cephalic fistula. A novel...
Next Document:  Retrieval of port-A catheter fragment from the main and right pulmonary arteries 3 years after dislo...